Filtern
Erscheinungsjahr
- 2014 (25) (entfernen)
Dokumenttyp
Sprache
- Englisch (25) (entfernen)
Schlagworte
- Safety (13)
- Sicherheit (13)
- Anfahrversuch (9)
- Deutschland (9)
- Germany (9)
- Bewertung (8)
- Evaluation (assessment) (8)
- Method (8)
- Compatibility (7)
- Fahrzeug (7)
This document describes the development and state of the art of orthotropic steel bridges in Germany. Following a short historical review of the performance of orthotropic bridge decks over the last decades, the present traffic loads are described and related to the resistance of the existing structures. Based on four different hazard categories, this paper describes different retrofitting methods. Although several promising strengthening techniques are introduced and evaluated, it appears that further research is urgently required in order to improve these techniques.
In the project SECMAN " SECurity MANual " a simple four-step procedure for the identification of critical road infrastructures, assessment of these infrastructures regarding various man-made threats and the determination of effective protection measures was developed. These methodologies are summarized and combined into a comprehensive best-practice manual which allows for a trans-national structured and holistic security-risk-management approach for owners and operators of road infrastructures in Europe. This paper presents the developed methodology starting from the assessment procedures of a network's criticality over an object's attractiveness and vulnerability to the selection process of appropriate protection measures.
The paper describes the development of transitions between different safety barriers in Germany but also in the context of the European standardization. In the paper practical and impact test expriences with transitions are shown. In view of the sheer number of theoretically possible combinations of safety barriers, the demand for testing every transition, even if the connecting safety barriers differ only slightly, appears to be economically unacceptable. On the other hand the experience from accidents and also from failed impact tests shows that transitions can be a risk to traffic safety. Therefore criteria for the distinction between transitions (impact test required/impact test unnecessary) are explained. In order to distinguish transitions which do not have to be impact-tested from those that require impact tests, criteria were developed and formulated.
Improving the security of critical road infrastructure is a major task for owners and operators of tunnels and bridges in the European TEN-T Network (Trans-European Networks of Transport) (European Parliament and Council 1996). Up to now, there has not been a systematic procedure for identifying and assessing critical infrastructure objects and selecting appropriate protection measures. The EC FP7 project SeRoN for the first time presents an innovative methodology in order to support road owners and operators in handling this complex task. This paper describes the methodology and project results in detail by giving an introduction into its practical application.
According to an investigation in March 2008 by the Federal Ministry of Transport, Building and Urban Affairs (BMVBS) about 14,000 truck parking spaces are missing in the near of motorways in Germany. Beside constructional enlargement of rest areas, intelligent traffic systems ought to be used to detect automatically the occupancy rate of rest areas and to provide better demand management and also to achieve an increase of capacity of truck parking spaces. The essay describes the newly developed control procedure "Compact parking", which is currently under development by German Federal Highway Research Institute (BASt). The method achieves that a number of trucks are parking in a compact way, side by side and without a driving lane between them. With the help of dynamic displays above the parking rows, the drivers receive the needful information to park their vehicle in a parking row, in which other trucks have the same or an earlier departure time. This system is able to increase the rest area capacity in short-term, more quickly than constructional enlargement of rest areas.
Due to the publication of guidelines in Germany the possibility exists to offer analytical designed construction works within an alternative proposal. But the extent to which the test specimen production influences the design relevant properties (for the same asphalt mixture) is not sufficiently investigated at present. Objective of this research project was to determine the design relevant asphalt properties by tests and do comparative considerations on two selected locations within the renewal of a federal trunk road (Germany). For the comparative consideration of the design relevant asphalt properties mixture samples were taken during paving and afterwards drill cores were taken at the same locations. Fatigue tests and tests to determine the stiffness were conducted with the Indirect Tensile Test (ITT). Then design calculations having regard to the test results were performed. At this different bearing conditions of the asphalt package were considered. The calculated fatigue conditions were comparative evaluated and they are presented and discussed in this paper.
Tempered road system
(2014)
The road performance is strongly influenced by climatic conditions. Winter conditions have massive impact on traffic security but also pavement lifetime decreases as an effect of temperature variation during wintertime and summertime. Heating and cooling of a pavement is a possibility to work against these impacts. To discuss the boundary conditions for an efficient construction and operation of a tempered road system a feasibility study has been made. The study shows the feasibility and identifies thermal energy buffering as a main challenge. When thinking of a fully regenerative operation of a large tempered road system (e.g. 20.000 m-²) the storage volume has to be too large for an economic and structurally engineered satisfactory solution. However, the location dependent usage of natural geothermal storage possibilities and as well smart alignment and construction promises a feasibility realization.
Various climate projections predict changing climatic parameters like temperature, precipitation, wind speed etc. for Germany. This could have severe impacts on road transport infrastructure as well as road traffic itself. At the Federal Highway Research Institute (Bundesanstalt für Straßenwesen (BASt) a strategy was developed to adapt roads and engineering structures to the impacts of climate change. The strategy "Anpassung der Straßenverkehrsinfrastruktur an den Klimawandel / Adaptation of the road infrastructure to climate change (AdSVIS)" comprises currently about 15 projects. On the basis of the identification of the hazards and the combination of the climate and road network data, the road transport infrastructure which might be affected is to be determined. Adaptation measures are to be developed for the identified risk areas and assessed as to their effectiveness. Special attention is given to international cooperation since climate change is a truly global challenge.
Although the bus belongs to the safest traffic means, single accidents can be particularly severe and concern many passengers. Especially in case of fires a high number of injured and killed persons can be the outcome. Fire safety of buses therefore is of high importance. With the increase of plastic materials as a material for the interior equipment of buses and coaches due to their good mechanical properties combined with low weight, the question arises whether the safety level has decreased in case of a fire during the last years " also compared to other means of transport. Because of the combustible plastics and their ability to release a high amount of heat the main fire load in buses is no longer the fuel but the plastic materials which are also often easy to ignite. Besides the flammability of the equipments, also the production of smoke, the smoke development and propagation as well as its toxicity are of interest. That counts for the passengers as well as for the test methods and its limit values. The severe fire in Germany near Hanover in 2008 with 20 fatalities showed how disastrous such fires can be. For those reasons several research projects were initiated on behalf of the German Federal Highway Research Institute. At the one hand the fire behaviour of coach interiors was examined in general focusing on fire propagation as well as fire detection and signalling. As result, recommendations with regard to early fire detection systems for the engine compartments and onboard extinguishing equipment were elaborated. On the other hand research was carried out to examine heat release, smoke, smoke propagation and its toxicity due to burning bus interior materials. In this project small and real scale experiments on material specimens, interior parts and vehicles were performed. Trains and buses often have very similar operation conditions. Consequently, bus interior material was tested according to the regulations for rail vehicles, i.e. DIN EN 45545 as well as DIN 5510. None of the tested bus interior materials would have been allowed to use in a train. The fire safety regulations for bus materials are on a low level compared to other transport sectors, i.e. railway, ship and aircraft. Also numerical investigations with the Fire Dynamics Simulator (FDS) were performed. The very rapid fire development during the severe bus fire from 2008 could be predicted with the numerical model. The model was then used to investigate the influence of different materials, ventilation conditions and ignition sources. The bus materials contribute significantly to a very rapid fire development in bus fires. Especially, the flammable ceiling and the passenger seats were identified to be key issues of the fire propagation in a bus and can be explained by the rapid fire spread along the ceiling and the high fire load of passenger seats. As conclusion of the project effective and economically reasonable fire safety requirements for interiors of buses are recommended which would improve the current situation. Proposals for amendments of current requirements are recommended including the specification of appropriate limit values. In particular, it is taken into consideration which reasonable fire safety standards from other transport sectors, especially the rail sector, should be transferred to buses
For the assessment of vehicle safety in frontal collisions compatibility (which consists of self and partner protection) between opponents is crucial. Although compatibility has been analysed worldwide for over 10 years, no final assessment approach has been defined to date. Taking into account the European Enhanced Vehicle safety Committee (EEVC) compatibility and the final report to the steering committee on frontal impact [Faerber 2007] and the FP5 VC-COMPAT[Edwards 2007] project activities, two test approaches were identified as the most promising candidates for the assessment of compatibility. Both are composed of an off-set and a full overlap test procedure. In addition another procedure (a test with a moving deformable barrier) is getting more attention in current research programmes. The overall objective of the FIMCAR project is to complete the development of the candidate test procedures and propose a set of test procedures suitable for regulatory application to assess and control a vehicle- frontal impact and compatibility crash safety. In addition an associated cost benefit analysis will be performed. In the FIMCAR Deliverable D 3.1 [Adolph 2013] the development and assessment of criteria and associated performance limits for the full width test procedure were reported. In this Deliverable D3.2 analyses of the test data (full width tests, car-to-car tests and component tests), further development and validation of the full width assessment protocol and development of the load cell and load cell wall specification are reported. The FIMCAR full-width assessment procedure consists of a 50 km/h test against the Full Width Deformable Barrier (FWDB). The Load Cell Wall behind the deformable element assesses whether or not important Energy Absorbing Structures are within the Common Interaction Zone as defined based on the US part 581 zone. The metric evaluates the row forces and requires that the forces directly above and below the centre line of the Common Interaction Zone exceed a minimum threshold. Analysis of the load spreading showed that metrics that rely on sum forces of rows and columns are within acceptable tolerances. Furthermore it was concluded that the Repeatability and Reproducibility of the FWDB test is acceptable. The FWDB test was shown to be capable to detect lower load paths that are beneficial in car-to-car impacts.