Sonstige
Filtern
Dokumenttyp
- Konferenzveröffentlichung (12) (entfernen)
Sprache
- Englisch (12) (entfernen)
Schlagworte
- Dummy (12) (entfernen)
Institut
- Abteilung Fahrzeugtechnik (12)
- Sonstige (12)
One main objective of the EU-Project SENIORS is to provide improved methods to assess thoracic injury risk to elderly occupants. In contribution to this task paired simulations with a THOR dummy model and human body model will be used to develop improved thoracic injury risk functions. The simulation results can provide data for injury criteria development in chest loading conditions that are underrepresented in PMHS test data sets that currently proposed risk functions are based on. To support this approach a new simplified generic but representative sled test fixture and CAE model for testing and simulation were developed. The parameter definition and evaluation of this sled test fixture and model is presented in this paper. The justification and definition of requirements for this test set-up was based on experience from earlier studies. Simple test fixtures like the gold standard sled fixture are easy to build and also to model in CAE, but provide too severe belt-only loading. On the other hand a vehicle buck including production components like airbag and seat is more representative, but difficult to model and to be replicated at a different laboratory. Furthermore some components might not be available for physical tests at later stage. The basis of the SENIORS generic sled test set-up is the gold standard fixture with a cable seat back and foot rest. No knee restraint was used. The seat pan design was modified including a seat ramp. The three-point belt system had a generic adjustable load limiter. A pre-inflated driver airbag assembly was developed for the test fixture. Results of THOR test and simulations in different configurations will be presented. The configurations include different deceleration pulses. Further parameter variations are related to the restraint system including belt geometry and load limiter levels. Additionally different settings of the generic airbag were evaluated. The test set-up was evaluated and optimized in tests with the THOR-M dummy in different test configurations. Belt restraint parameters like D-ring position and load limiter setting were modified to provide moderate chest loading to the occupant. This resulted in dummy readings more representative of the loading in a contemporary vehicle than most available PMHS sled tests reported in the literature. However, to achieve a loading configuration that exposes the occupant to even less severe loading comparable to modern vehicle restraints it might be necessary to further modify the test set-up. The new generic sled test set-up and a corresponding CAE model were developed and applied in tests and simulations with THOR. Within the SENIORS project with this test set-up also volunteer and PMHS as well as HBM simulations are performed, which will be reported in other publications. The test environment can contribute in future studies to the assessment of existing and new frontal impact dummies as well as dummy improvements and related instrumentation. The test set-up and model could also serve as a new standard test environment for PMHS and volunteer tests as well as HBM simulations.
In the European Project FIMCAR, a proposal for a frontal impact test configuration was developed which included an additional full width deformable barrier (FWDB) test. Motivation for the deformable element was partly to measure structural forces as well as to produce a severe crash pulse different from that in the offset test. The objective of this study was to analyze the safety performance of vehicles in the full width rigid barrier test (FWRB) and in the full width deformable barrier test (FWDB). In total, 12 vehicles were crashed in both configurations. Comparison of these tests to real world accident data was used to identify the crash barrier most representative of real world crashes. For all vehicles, the airbag visible times were later in the FWDB configuration. This was attributed to the attenuation of the initial acceleration peak, observed in FWRB tests, by the addition of the deformable element. These findings were in alignment with airbag triggering times seen in real world crash data. Also, the dummy loadings were slightly worse in FWDB compared to FWRB tests, which is possibly linked to the airbag firing and a more realistic loading of the vehicle crash structures in the FWDB configuration. Evaluations of the lower extremities have shown a general increasing of the tibia index with the crash pulse severity.
The frontal crash is still an important contributor to deaths and serious injured resulting from road accidents in Europe. As the Hybrid-III dummy used in crash tests is over two decades old, the European Enhanced Vehicle-safety Committee is studying the potential for a new test device. Key is the availability of a well-defined set of requirements that identifies the minimum level of biofidelity required for an advanced frontal dummy. In this paper, a complete set of frontal impact biofidelity requirements, consisting of references , description of test conditions and corridors, is presented.
The European Enhanced Vehicle-safety Committee wants to promote the use of more biofidelic child dummies and biomechanical based tolerance limits in regulatory and consumer testing. This study has investigated the feasibility and potential impact of Q-dummies and new injury criteria for child restraint system assessment in frontal impact. European accident statistics have been reviewed for all ECE-R44 CRS groups. For frontal impact, injury measures are recommended for the head, neck, chest and abdomen. Priority of body segment protection depends on the ECE-R44 group. The Q-dummy family is able to reflect these injuries, because of its biofidelity performance and measurement capabilities for these body segments. Currently, the Q0, Q1, Q1.5, Q3 and Q6 are available representing children of 0, 1, 1.5, 3 and 6 years old. These Q-dummies cover almost all dummy weight groups as defined in ECE-R44. Q10, representing a 10 year-old child, is under development. New child dummy injury criteria are under discussion in EEVC WG12. Therefore, the ECE-R44 criteria are assessed by comparing the existing P-dummies and new Q-dummies in ECE-R44 frontal impact sled tests. In total 300 tests covering 30 CRSs of almost all existing child seat categories are performed by 11 European organizations. From this benchmark study, it is concluded that the performance of the Q-dummy family is good with respect to repeatability of the measurement signals and the durability of the dummies. Applying ECE-R44 criteria, the first impression is that results for P- and Q-dummy are similar. For child seat evaluation the potential merits of the Q-dummy family lie in the extra measurement possibilities of these dummies and in the more biofidelic response.
In the EC FP6 Integrated Project Advanced Protection Systems, APROSYS, the first WorldSID small female prototype was developed and evaluated by BASt, FTSS, INRETS, TRL and UPM-INSIA during 2006 and 2007. Results were presented at the ESV 2007 conference (Been et al., 2007). With the prototype dummy scoring a biofidelity rating higher than 6.7 out of 10 according to ISO/TR9790, the results were very promising. Also opportunities for further development were identified by the evaluation group. A revised prototype, Revision1, was subsequently developed in the 2007-2008 period to address comments from the evaluation group. The Revision1 dummy includes changes in the half arms and the suit (anthropometry and arm biomechanics), the thorax and abdomen ribs and sternum (rib durability), the abdomen/lumbar area and the lower legs (mass distribution). Also a two-dimensional chest deflection measurement system was developed to measure deflection in both lateral and anterior-posterior direction to improve oblique thorax loading sensitivity. Two Revision1 prototype dummies have now been evaluated by FTSS, TRL, UPM-INSIA and BASt. The updated prototype dummies were subjected to an extensive matrix of biomechanical tests, such as full body pendulum tests and lateral sled impact tests as specified by Wayne State University, Heidelberg University and Medical College of Wisconsin. The results indicated a significant improvement of dummy biofidelity. The overall dummy biofidelity in the ISO rating system has significantly improved from 6.7 to 7.6 on a scale between 0-10. The small female WorldSID has now obtained the same biofidelity rating as the WorldSID mid size male dummy. Also repeatability improved with respect to the prototype. In conclusion the recommended updates were all executed and all successfully contributed in achieving improved performance of the dummy.
A legform impactor with biofidelic characteristics (FlexPLI) which is being developed by the Japanese Automobile Research Institute (JARI) is being considered as a test tool for legislation within a proposed Global Technical Regulation on pedestrian protection (UNECE, 2006) and therefore being evaluated by the Technical Evaluation Group (TEG) of GRSP. In previous built levels it already showed good test results on real cars as well as under idealised test conditions but also revealed further need for improvement. A research study at the Federal Highway Research Institute (BASt) deals with the question on how leg injury risks of modern car fronts can be revealed, reflected and assessed by the FlexPLI and how the impactor can be used and implemented as a legislative instrument for the type approval of cars according to current and future legislations on pedestrian protection. The latest impactor built level (GTα ) is being evaluated by a general review and assessment of the certification procedure, the knee joint biofidelity and the currently proposed injury criteria. Furthermore, the usability, robustness and durability as a test tool for legislation is examined and an assessment of leg injuries is made by a series of tests with the FlexPLI on real cars with modern car front shapes as well as under idealised test conditions. Finally, a comparison is made between the FlexPLI and the current european legislation tool, the legform impactor according to EEVC WG 17.
The PDB, BASt and Opel conducted two test series to evaluate possible effects on the results obtained using the EEVC WG17 Lower Legform Impactor as a test tool for the assessment of pedestrian safety. The reproducibility and repeatability of the test results were assessed using six legform impactors while keeping the test parameters constant. In the second series one impactor was used and the test parameters were varied to assess the effects on the readings of the legform. The test parameters were velocity, temperature, relative humidity, the point of first contact regarding the deviation in z-direction and the deviations of the pitch, roll and yaw angle. The tests were performed using an inverse setup, i.e. the legform was hit by a guided linear impactor equipped with a honeycomb deformation element. This setup was chosen to be able to vary each single parameter while avoiding variations of the other test parameters at the same time. The test parameters were varied stronger than allowed in regulatory use in order to determine possible dependencies between the parameters and the readings which were acceleration, bending angle and shear displacement.
A flexible pedestrian legform impactor (FlexPLI) has been evaluated by a Technical Evaluation Group (Flex-TEG) of the Working Party on Passive Safety (GRSP) of the United Nations Economic Commission for Europe (UN-ECE). It will be implemented within phase 2 of the global technical regulation (GTR 9) as well as within a new ECE regulation on pedestrian safety as a test tool for the assessment of lower extremity injuries in lateral vehicle-to-pedestrian accidents (UN-ECE 2010-1, 2010-2 and 2010-3). Due to its biofidelic properties in the knee and tibia section, the FlexPLI is found to having an improved knee and tibia injury assessment ability when being compared to the current legislative test tool, the lower legform impactor developed by the Pedestrian Safety Working Group of the European Enhanced Vehicle-safety Committee (EEVC WG 17). However, due to a lack of biofidelity in terms of kinematics and loadings in the femur part of the FlexPLI, an appropriate assessment of femur injuries is still outstanding. The study described in this paper is aimed to close this gap. Impactor tests with the FlexPLI at different impact heights on three vehicle frontends with Sedan, SUV and FFV shape are performed and compared to tests with a modified FlexPLI with upper body mass. Full scale validation tests using a modified crash test dummy with attached FlexPLI that are carried out for the first time prove the more humanlike responses of the femur section with applied upper body mass. Apart from that they also show that the impact conditions described in the current technical provisions for tests with the FlexPLI don"t necessarily compensate the missing torso mass in terms of knee and tibia loadings either. Therefore it can be concluded that an applied upper body mass will contribute to a more biofidelic overall behavior of the legform and subsequently an improved injury assessment ability of all lower extremity injuries addressed by the FlexPLI. Nevertheless, the validity of the original as well as the modified legform for tests against vehicles with extraordinary high bumpers as well as flat front vehicles still needs to be evaluated in detail. A first clue is given by the application of an additional accelerometer to the legform.
It is well known that most accidents with pedestrians are caused by the driver not being alert or misinterpreting the situation. For that reason advanced forward looking safety systems have a high potential to improve safety for this group of vulnerable road users. Active pedestrian protection systems combine reduction of impact speed by driver warning and/or autonomous braking with deployment of protective devices shortly before the imminent impact. According to the Euro NCAP roadmap the Autonomous Emergency Braking system tests for Pedestrians Protection will be set in force from 2016 onwards. Various projects and organisations in Europe are developing performance tests and assessment procedures as accompanying measures to the Euro NCAP initiative. To provide synthesised input to Euro NCAP so-called Harmonisation Platforms (HP-) have been established. Their main goal is to foster exchange of information on key subjects, thereby generating a clear overview of similarities and differences on the approaches chosen and, on that basis, recommend on future test procedures. In this paper activities of the Harmonisation Platform 2 on the development of Test Equipment are presented. For the testing targets that mimic humans different sensing technologies are required. A first set of specifications for pedestrian targets and the propulsion systems as collected by Harmonisation Platform 2 are presented together with a first evaluation for a number of available tools.
A flexible pedestrian legform impactor (FlexPLI) with biofidelic characteristics is aimed to be implemented within global legislation on pedestrian protection. Therefore, it is being evaluated by a technical evaluation group (Flex-TEG) of GRSP with respect to its biofidelity, robustness, durability, usability and protection level (Zander, 2008). Previous studies at the Federal Highway Research Institute (BASt) and other laboratories already showed good progress concerning the general development, but also the need for further improvement and further research in various areas. An overview is provided of the different levels of development and all kinds of evaluation activities of the Flex-TEG, starting with the Polar II full scale pedestrian dummy as its origin and ending up with the latest legform impactor built level GTR that is expected to be finalized by the end of the year 2009. Using the latest built levels as a basis, gaps are revealed that should be closed by future developments, like the usage of an upper body mass (UBM), the validation of the femur loads, injury risk functions for the cruciate knee ligaments and an appropriate certification method. A recent study on an additional upper body mass being applied for the first time to the Flex-GT is used as means of validation of recently proposed modified impact conditions. Therefore, two test series on a modern vehicle front using an impactor with and without upper body mass are compared. A test series with the Flex-GTR will be used to study both the comparability of the impact behavior of the GT and GTR built level as well as the consistency of test results. Recommendations for implementation within legislation on pedestrian protection are made.