One main objective of the EU-Project SENIORS is to provide improved methods to assess thoracic injury risk to elderly occupants. In contribution to this task paired simulations with a THOR dummy model and human body model will be used to develop improved thoracic injury risk functions. The simulation results can provide data for injury criteria development in chest loading conditions that are underrepresented in PMHS test data sets that currently proposed risk functions are based on. To support this approach a new simplified generic but representative sled test fixture and CAE model for testing and simulation were developed. The parameter definition and evaluation of this sled test fixture and model is presented in this paper. The justification and definition of requirements for this test set-up was based on experience from earlier studies. Simple test fixtures like the gold standard sled fixture are easy to build and also to model in CAE, but provide too severe belt-only loading. On the other hand a vehicle buck including production components like airbag and seat is more representative, but difficult to model and to be replicated at a different laboratory. Furthermore some components might not be available for physical tests at later stage. The basis of the SENIORS generic sled test set-up is the gold standard fixture with a cable seat back and foot rest. No knee restraint was used. The seat pan design was modified including a seat ramp. The three-point belt system had a generic adjustable load limiter. A pre-inflated driver airbag assembly was developed for the test fixture. Results of THOR test and simulations in different configurations will be presented. The configurations include different deceleration pulses. Further parameter variations are related to the restraint system including belt geometry and load limiter levels. Additionally different settings of the generic airbag were evaluated. The test set-up was evaluated and optimized in tests with the THOR-M dummy in different test configurations. Belt restraint parameters like D-ring position and load limiter setting were modified to provide moderate chest loading to the occupant. This resulted in dummy readings more representative of the loading in a contemporary vehicle than most available PMHS sled tests reported in the literature. However, to achieve a loading configuration that exposes the occupant to even less severe loading comparable to modern vehicle restraints it might be necessary to further modify the test set-up. The new generic sled test set-up and a corresponding CAE model were developed and applied in tests and simulations with THOR. Within the SENIORS project with this test set-up also volunteer and PMHS as well as HBM simulations are performed, which will be reported in other publications. The test environment can contribute in future studies to the assessment of existing and new frontal impact dummies as well as dummy improvements and related instrumentation. The test set-up and model could also serve as a new standard test environment for PMHS and volunteer tests as well as HBM simulations.
Thorax injury is one of main causes of serious injury in frontal collisions, especially for elderly car occupants. The anthropometric test device (ATD) THOR‐M provides chest deflection measurements at multiple locations, to assess the risk of thorax injury. For this purpose e, risk functions are needed that relate the potential criteria based on multipoint chest deflection measurement to in jury risk. Different thorax injury criteria and risk functions for THOR have been proposed [2‐3]. The criteria and functions are based on the traditional approach to developing injury risk functions using matched ATD and PMHS tests by relating the injury (number of fractures) to injury criteria. Regarding these studies, some limitations have been identified, in particular concerning the loading conditions of the data used (mainly 3‐point‐belt loading, high loading severity, out‐of‐date ATD versions. To extend the data set and overcome these limitations, a new approach for improved thorax injury criteria was applied within the EC‐funded project SENIORS. The new approach is based on matched frontal impact sled computer simulations with a model representing the latest THOR‐M ATD version, and matching simulations with a human body model (HBM) representing an elderly car occupant.
Thoracic injuries are one of the main causes of fatally and severely injured casualties in car crashes. Advances in restraint system technology and airbags may be needed to address this problem; however, the crash test dummies available today for studying these injuries have limitations that prevent them from being able to demonstrate the benefits of such innovations. THORAX-FP7 was a collaborative medium scale project under the European Seventh Framework. It focused on the mitigation and prevention of thoracic injuries through an improved understanding of the thoracic injury mechanisms and the implementation of this understanding in an updated design for the thorax-shoulder complex of the THOR dummy. The updated dummy should enable the design and evaluation of advanced restraint systems for a wide variety (gender, age and size) of car occupants. The hardware development involved five steps: 1) Identification of the dominant thoracic injury types from field data, 2) Specification of biomechanical requirements, 3) Identification of injury parameters and necessary instrumentation, 4) Dummy hardware development and 5) Evaluation of the demonstrator dummy. The activities resulted in the definition of new biofidelity and instrumentation requirements for an updated thorax-shoulder complex. Prototype versions were realised and implemented in three THOR dummies for biomechanical evaluation testing. This paper documents the hardware developments and biomechanical evaluation testing carried out.
The European Enhanced Vehicle-safety Committee wants to promote the use of more biofidelic child dummies and biomechanical based tolerance limits in regulatory and consumer testing. This study has investigated the feasibility and potential impact of Q-dummies and new injury criteria for child restraint system assessment in frontal impact. European accident statistics have been reviewed for all ECE-R44 CRS groups. For frontal impact, injury measures are recommended for the head, neck, chest and abdomen. Priority of body segment protection depends on the ECE-R44 group. The Q-dummy family is able to reflect these injuries, because of its biofidelity performance and measurement capabilities for these body segments. Currently, the Q0, Q1, Q1.5, Q3 and Q6 are available representing children of 0, 1, 1.5, 3 and 6 years old. These Q-dummies cover almost all dummy weight groups as defined in ECE-R44. Q10, representing a 10 year-old child, is under development. New child dummy injury criteria are under discussion in EEVC WG12. Therefore, the ECE-R44 criteria are assessed by comparing the existing P-dummies and new Q-dummies in ECE-R44 frontal impact sled tests. In total 300 tests covering 30 CRSs of almost all existing child seat categories are performed by 11 European organizations. From this benchmark study, it is concluded that the performance of the Q-dummy family is good with respect to repeatability of the measurement signals and the durability of the dummies. Applying ECE-R44 criteria, the first impression is that results for P- and Q-dummy are similar. For child seat evaluation the potential merits of the Q-dummy family lie in the extra measurement possibilities of these dummies and in the more biofidelic response.
The frontal crash is still an important contributor to deaths and serious injured resulting from road accidents in Europe. As the Hybrid-III dummy used in crash tests is over two decades old, the European Enhanced Vehicle-safety Committee is studying the potential for a new test device. Key is the availability of a well-defined set of requirements that identifies the minimum level of biofidelity required for an advanced frontal dummy. In this paper, a complete set of frontal impact biofidelity requirements, consisting of references , description of test conditions and corridors, is presented.
In the EC FP6 Integrated Project Advanced Protection Systems, APROSYS, the first WorldSID small female prototype was developed and evaluated by BASt, FTSS, INRETS, TRL and UPM-INSIA during 2006 and 2007. Results were presented at the ESV 2007 conference (Been et al., 2007). With the prototype dummy scoring a biofidelity rating higher than 6.7 out of 10 according to ISO/TR9790, the results were very promising. Also opportunities for further development were identified by the evaluation group. A revised prototype, Revision1, was subsequently developed in the 2007-2008 period to address comments from the evaluation group. The Revision1 dummy includes changes in the half arms and the suit (anthropometry and arm biomechanics), the thorax and abdomen ribs and sternum (rib durability), the abdomen/lumbar area and the lower legs (mass distribution). Also a two-dimensional chest deflection measurement system was developed to measure deflection in both lateral and anterior-posterior direction to improve oblique thorax loading sensitivity. Two Revision1 prototype dummies have now been evaluated by FTSS, TRL, UPM-INSIA and BASt. The updated prototype dummies were subjected to an extensive matrix of biomechanical tests, such as full body pendulum tests and lateral sled impact tests as specified by Wayne State University, Heidelberg University and Medical College of Wisconsin. The results indicated a significant improvement of dummy biofidelity. The overall dummy biofidelity in the ISO rating system has significantly improved from 6.7 to 7.6 on a scale between 0-10. The small female WorldSID has now obtained the same biofidelity rating as the WorldSID mid size male dummy. Also repeatability improved with respect to the prototype. In conclusion the recommended updates were all executed and all successfully contributed in achieving improved performance of the dummy.
In the European Project FIMCAR, a proposal for a frontal impact test configuration was developed which included an additional full width deformable barrier (FWDB) test. Motivation for the deformable element was partly to measure structural forces as well as to produce a severe crash pulse different from that in the offset test. The objective of this study was to analyze the safety performance of vehicles in the full width rigid barrier test (FWRB) and in the full width deformable barrier test (FWDB). In total, 12 vehicles were crashed in both configurations. Comparison of these tests to real world accident data was used to identify the crash barrier most representative of real world crashes. For all vehicles, the airbag visible times were later in the FWDB configuration. This was attributed to the attenuation of the initial acceleration peak, observed in FWRB tests, by the addition of the deformable element. These findings were in alignment with airbag triggering times seen in real world crash data. Also, the dummy loadings were slightly worse in FWDB compared to FWRB tests, which is possibly linked to the airbag firing and a more realistic loading of the vehicle crash structures in the FWDB configuration. Evaluations of the lower extremities have shown a general increasing of the tibia index with the crash pulse severity.
Das Ziel der Untersuchung war, die Grenzen der Belastbarkeit eines Rollstuhl- und Personenrückhaltesystems mit Kraftknoten nach DIN 75078-2 zu ermitteln. Dazu wurden dynamische Schlittenversuche durchgeführt, bei denen die Verzögerungspulse sowie das Gesamtgewicht von Rollstuhl und Prüfpuppe variiert wurden. Für die Untersuchungen kamen ein Prüfrollstuhl, definiert nach ISO 10542, und Rückhaltesysteme mit Kraftknoten gemäß DIN 75078-2 zum Einsatz. Das Rückhaltesystem bestand aus einem Rollstuhl- und einem Personenrückhaltesystem, wobei das Rollstuhlrückhaltesystem (RRS) mit vier bzw. sechs Gurten und entsprechenden Retraktoren an einem dynamischen Schlittenaufbau befestigt wurde. Das Personenrückhaltesystem (PRS) bestand aus einem am Rollstuhl integrierten Beckengurt sowie einem Schulterschräggurt, der am Beckengurt und am Schlittenaufbau befestigt wurde. Ferner wurden bei den Versuchen Prüfpuppen verschiedener Alters- und Gewichtsklassen (P6, HIII 5 %, HIII 50 % und HIII 95 %) eingesetzt Die Belastungsanforderungen für das Rückhaltesystem wurden sukzessiv erweitert, indem einerseits das Gesamtgewicht (Rollstuhl und Prüfpuppe) und andererseits auch die Verzögerungspulse bis zur Versagensgrenze erhöht wurden. Das Vier-Gurt-Rückhaltesystem konnte bei einem Verzögerungspuls von 10 g einem Gesamtgewicht von bis zu 221 kg standhalten. Bei einem Verzögerungspuls von 20 g und einem Gesamtgewicht von 134 kg wurde das Vier-Gurt-System bis über die Grenzen belastet. Das Sechs-Gurt-Rückhaltesystem hat Belastungen bis 221 kg standgehalten. Infolgedessen ist bei einer Erhöhung der Verzögerungspulse auf 20 g und einem Gesamtgewicht von mehr als 109 kg ein Sechs-Gurt-System zu empfehlen.
The European Enhanced Vehicle-safety Committee (EEVC) Working Group 13 for Side Impact Protection has been developing an Interior Headform Test Procedure to complement the full-scale Side Impact Test Procedure for Europe and for the proposed IHRA test procedures. In real world accidents interior head contacts with severe head injuries still occur, which are not always observed in standard side impact tests with dummies. Thus a means is needed to encourage further progress in head protection. At the 2003 ESV-Conference EEVC Working Group 13 reported the results on Interior Headform Testing. Further research has been performed since and the test procedure has been improved. This paper gives an overview of its latest status. The paper presents new aspects which are included in the latest test procedure and the research work leading to these enhancements. One topic of improvement is the definition of the Free Motion Headform (FMH) impactor alignment procedure to provide guidelines to minimize excessive headform chin contact and to minimize potential variability. Research activities have also been carried out on the definition of reasonable approach head angles to avoid unrealistic test conditions. Further considerations have been given to the evaluation of head airbags, their potential benefits and a means of ensuring protection for occupants regardless of seating position and sitting height. The paper presents the research activities that have been made since the last ESV Conference in 2003 and the final proposal of the EEVC Headform Test Procedure.