Thoracic injuries are one of the main causes of fatally and severely injured casualties in car crashes. Advances in restraint system technology and airbags may be needed to address this problem; however, the crash test dummies available today for studying these injuries have limitations that prevent them from being able to demonstrate the benefits of such innovations. THORAX-FP7 was a collaborative medium scale project under the European Seventh Framework. It focused on the mitigation and prevention of thoracic injuries through an improved understanding of the thoracic injury mechanisms and the implementation of this understanding in an updated design for the thorax-shoulder complex of the THOR dummy. The updated dummy should enable the design and evaluation of advanced restraint systems for a wide variety (gender, age and size) of car occupants. The hardware development involved five steps: 1) Identification of the dominant thoracic injury types from field data, 2) Specification of biomechanical requirements, 3) Identification of injury parameters and necessary instrumentation, 4) Dummy hardware development and 5) Evaluation of the demonstrator dummy. The activities resulted in the definition of new biofidelity and instrumentation requirements for an updated thorax-shoulder complex. Prototype versions were realised and implemented in three THOR dummies for biomechanical evaluation testing. This paper documents the hardware developments and biomechanical evaluation testing carried out.
A flexible pedestrian legform impactor (FlexPLI) has been evaluated by a Technical Evaluation Group (Flex-TEG) of the Working Party on Passive Safety (GRSP) of the United Nations Economic Commission for Europe (UN-ECE). It will be implemented within phase 2 of the global technical regulation (GTR 9) as well as within a new ECE regulation on pedestrian safety as a test tool for the assessment of lower extremity injuries in lateral vehicle-to-pedestrian accidents (UN-ECE 2010-1, 2010-2 and 2010-3). Due to its biofidelic properties in the knee and tibia section, the FlexPLI is found to having an improved knee and tibia injury assessment ability when being compared to the current legislative test tool, the lower legform impactor developed by the Pedestrian Safety Working Group of the European Enhanced Vehicle-safety Committee (EEVC WG 17). However, due to a lack of biofidelity in terms of kinematics and loadings in the femur part of the FlexPLI, an appropriate assessment of femur injuries is still outstanding. The study described in this paper is aimed to close this gap. Impactor tests with the FlexPLI at different impact heights on three vehicle frontends with Sedan, SUV and FFV shape are performed and compared to tests with a modified FlexPLI with upper body mass. Full scale validation tests using a modified crash test dummy with attached FlexPLI that are carried out for the first time prove the more humanlike responses of the femur section with applied upper body mass. Apart from that they also show that the impact conditions described in the current technical provisions for tests with the FlexPLI don"t necessarily compensate the missing torso mass in terms of knee and tibia loadings either. Therefore it can be concluded that an applied upper body mass will contribute to a more biofidelic overall behavior of the legform and subsequently an improved injury assessment ability of all lower extremity injuries addressed by the FlexPLI. Nevertheless, the validity of the original as well as the modified legform for tests against vehicles with extraordinary high bumpers as well as flat front vehicles still needs to be evaluated in detail. A first clue is given by the application of an additional accelerometer to the legform.
Thoracic injury is one of the predominant types of severe injuries in frontal accidents. The assessment of the injury risk to the thorax in the current frontal impact test procedures is based on the uni-axial chest deflection measured in the dummy Hybrid III. Several studies have shown that criteria based on the linear chest potentiometer are not sensitive enough to distinguish between different restraint systems, and cannot indicate asymmetric chest loading, which has been shown to correlate to increased injury risk. Furthermore, the measurement is sensitive to belt position on the dummy chest. The objective of this study was to evaluate the optical multipoint chest deflection measurement system "RibEye" in frontal impact sled tests. Therefore the sensitivity of the RibEyesystem to different restraint system parameters was investigated. Furthermore, the issue of signal drop out at the 6 th rib was investigated in this study.A series of sled tests were conducted with the RibEye system in the Hybrid III 50%. The sled environment consisted of a rigid seat and a standard production three-point seat belt system. Rib deflections were recorded with the RibEye system and additionally with the standard chest potentiometer. The tests were carried out at crash pulses of two different velocities (30 km/h and 64 km/h). The tests were conducted with different belt routing to investigate the sensitivity of chest deflection measurements to belt position on the dummy chest. Furthermore, different restraint system parameters were investigated (force limiter level, with or without pretensioning) to evaluate if the RibEye measurements provide additional information to distinguish between restraint system configurations . The results showed that with the RibEye system it was possible to identify the effect of belt routing in more detail. The chest deflections measured with the standard chest potentiometer as well as the maximum deflection measured by RibEye allowed the distinction to be made between different force limiter levels. The RibEye system was also able to clearly show the asymmetric deflection of the rib cage due to belt loading. In some configurations, differences of more than 15 mm were observed between the left and side areas of the chest. Furthermore, the abdomen insert was identified as source of the problem of signal drop out at the 6th rib. Possible solutions are discussed. In conclusion, the RibEye system provided valuable additional information regarding the assessment of restraint systems. It has the potential to enable the evaluation of thoracic injury risk due to asymmetric loading. Further investigations with the RibEye should be extended to tests in a vehicle environment, which include a vehicle seat and other restraint system components such as an airbag.
It is well known that most accidents with pedestrians are caused by the driver not being alert or misinterpreting the situation. For that reason advanced forward looking safety systems have a high potential to improve safety for this group of vulnerable road users. Active pedestrian protection systems combine reduction of impact speed by driver warning and/or autonomous braking with deployment of protective devices shortly before the imminent impact. According to the Euro NCAP roadmap the Autonomous Emergency Braking system tests for Pedestrians Protection will be set in force from 2016 onwards. Various projects and organisations in Europe are developing performance tests and assessment procedures as accompanying measures to the Euro NCAP initiative. To provide synthesised input to Euro NCAP so-called Harmonisation Platforms (HP-) have been established. Their main goal is to foster exchange of information on key subjects, thereby generating a clear overview of similarities and differences on the approaches chosen and, on that basis, recommend on future test procedures. In this paper activities of the Harmonisation Platform 2 on the development of Test Equipment are presented. For the testing targets that mimic humans different sensing technologies are required. A first set of specifications for pedestrian targets and the propulsion systems as collected by Harmonisation Platform 2 are presented together with a first evaluation for a number of available tools.
A flexible pedestrian legform impactor (FlexPLI) with biofidelic characteristics is aimed to be implemented within global legislation on pedestrian protection. Therefore, it is being evaluated by a technical evaluation group (Flex-TEG) of GRSP with respect to its biofidelity, robustness, durability, usability and protection level (Zander, 2008). Previous studies at the Federal Highway Research Institute (BASt) and other laboratories already showed good progress concerning the general development, but also the need for further improvement and further research in various areas. An overview is provided of the different levels of development and all kinds of evaluation activities of the Flex-TEG, starting with the Polar II full scale pedestrian dummy as its origin and ending up with the latest legform impactor built level GTR that is expected to be finalized by the end of the year 2009. Using the latest built levels as a basis, gaps are revealed that should be closed by future developments, like the usage of an upper body mass (UBM), the validation of the femur loads, injury risk functions for the cruciate knee ligaments and an appropriate certification method. A recent study on an additional upper body mass being applied for the first time to the Flex-GT is used as means of validation of recently proposed modified impact conditions. Therefore, two test series on a modern vehicle front using an impactor with and without upper body mass are compared. A test series with the Flex-GTR will be used to study both the comparability of the impact behavior of the GT and GTR built level as well as the consistency of test results. Recommendations for implementation within legislation on pedestrian protection are made.
According to the German road traffic regulations children up to the age of 12 or a height below 150 cm have to use approved and appropriate child restraint systems (CRS). CRS must be approved according to UN-ECE Regulation No. 44. The regulation classifies CRS in 5 weight categories. The upper weight group is approved for children from 22 to 36 kg. However, studies show that already today many children weigh more than 36 kg although they have not reached a height of 150 cm. Therefore, no ECE R44 approved CRS is available for these overweight children. In conclusion, today's sizes and weights of children are no longer represented by the current version of the ECE R44. The heaviest used dummy (P10) weighs just 32.6 kg and has a height of 137.9 cm. Statistical data of German children show that already 5% of the children at a height of 137.9 cm have a weight above 45.3 kg. Regarding children at a height of 145 cm, the 95th percentile limit is at a weight of 53.3 kg. Based on these data 4 dummies with different heights and weights were defined and produced. Two of them are overweight. Up to now, there is no experience how current child restraint systems perform in a car crash if they are used by children with a weight above 36 kg and a height smaller than 150 cm. In the future, different child restraint systems will be tested with respect to the ECE R44 regulation using these overweight dummies.
Evaluation of the performance of competitive headforms as test tools for interior headform testing
(2009)
The European Research Project APROSYS has evaluated the interior headform test procedure developed by EEVC WG 13, representing the head contact in the car during a lateral impact. One important aspect within this test procedure was the selection of an appropriate impactor. The WG13 procedure currently uses the Free Motion Headform as used within the FMVSS 201. The ACEA 3.5 kg headform used in Phase 1 of the European Directive and the future European Regulation on Pedestrian Protection is still discussed as a possible alternative. This paper reports work performed by the Federal Highway Research Institute (BASt) as a part of the APROSYS Task 1.1.3. The study compares the two headform impactors according to FMVSS and ACEA, in a series of basic tests in order to evaluate their sensitivity towards different impact angles, impact accuracy, the effect of differences to impactors of the same type and the effects of the repeatability and reproducibility of the test results. The test surface consisted of a steel tube covered with PU foam and PVC, representing the car interior to be tested. Despite of the higher mass of the FMH the HIC values of this impactor were generally lower than those of the ACEA headform. The FMH showed a higher repeatability of test results but a high sensitivity on the angle of roll, the spherical ACEA impactor performed better with regards to the reproducibility. In case of the ACEA impactor-, the angle of roll had no influence.
Falltests zur Untersuchung der Belastungen von Dummys beim Aufprall auf den Boden, Teil 1 und 2
(2010)
Beim Zusammenprall eines Motorrads mit einem Pkw unterscheidet man in der Unfallforschung sowohl den Erstanprall des Motorradfahrers an den Pkw als auch den Sekundäraufprall des Motorradfahrers auf dem Boden. So genannte Full-Scale-Crashtests mit Dummys haben beim Erstanprall gezeigt, dass Motorradfahrer durch Airbags potenziell geschützt werden können. Bei den entsprechenden Unfallsimulationen wurde jedoch im weiteren Bewegungsablauf beim nachfolgenden Sekundäraufprall auf dem Boden festgestellt, dass relativ hohe Belastungen auf den Dummy einwirken. Es stellt sich hierbei jedoch die Frage, ob die üblicherweise für Lasteinwirkungen im Falle eines Erstanpralls entwickelten und validierten Dummys die bei einem Sekundäraufprall auf einen Motorradfahrer einwirkenden Belastungen hinreichend genau wiedergeben können. Dazu wurden die Belastungen eines Dummys beim Aufprall auf den Boden untersucht, um das Verletzungsrisiko eines menschlichen Motorradfahrers einschätzen zu können. Im Dekra-Crash-Test-Center wurden vier verschiedene Aufprallsituationen mit einem Hybrid III Dummy durchgeführt, wobei diese Tests an eine andere Testreihe angelehnt sind, die bereits am US-amerikanischen Institut "Dynamic Research International" (DRI) durchgeführt worden waren. Nach der Erläuterung des Testaufbaus und seiner Durchführung wird detailliert auf die gemessenen Verzögerungsbelastungen des Dummys eingegangen. Hierbei geben zum einen Tabellen eine Übersicht über charakteristische Messwerte zur Quantifizierung der maximalen Belastung des Dummys, zum anderen veranschaulichen Bilder die zugehörigen zeitlichen Verzögerungsverläufe in Becken, Brust und Kopf des Dummys. Der Artikel schließt mit einer Interpretation der Versuchsergebnisse und gibt einen Ausblick auf den weiteren Untersuchungsbedarf.