The frontal crash is still an important contributor to deaths and serious injured resulting from road accidents in Europe. As the Hybrid-III dummy used in crash tests is over two decades old, the European Enhanced Vehicle-safety Committee is studying the potential for a new test device. Key is the availability of a well-defined set of requirements that identifies the minimum level of biofidelity required for an advanced frontal dummy. In this paper, a complete set of frontal impact biofidelity requirements, consisting of references , description of test conditions and corridors, is presented.
The European Enhanced Vehicle-safety Committee wants to promote the use of more biofidelic child dummies and biomechanical based tolerance limits in regulatory and consumer testing. This study has investigated the feasibility and potential impact of Q-dummies and new injury criteria for child restraint system assessment in frontal impact. European accident statistics have been reviewed for all ECE-R44 CRS groups. For frontal impact, injury measures are recommended for the head, neck, chest and abdomen. Priority of body segment protection depends on the ECE-R44 group. The Q-dummy family is able to reflect these injuries, because of its biofidelity performance and measurement capabilities for these body segments. Currently, the Q0, Q1, Q1.5, Q3 and Q6 are available representing children of 0, 1, 1.5, 3 and 6 years old. These Q-dummies cover almost all dummy weight groups as defined in ECE-R44. Q10, representing a 10 year-old child, is under development. New child dummy injury criteria are under discussion in EEVC WG12. Therefore, the ECE-R44 criteria are assessed by comparing the existing P-dummies and new Q-dummies in ECE-R44 frontal impact sled tests. In total 300 tests covering 30 CRSs of almost all existing child seat categories are performed by 11 European organizations. From this benchmark study, it is concluded that the performance of the Q-dummy family is good with respect to repeatability of the measurement signals and the durability of the dummies. Applying ECE-R44 criteria, the first impression is that results for P- and Q-dummy are similar. For child seat evaluation the potential merits of the Q-dummy family lie in the extra measurement possibilities of these dummies and in the more biofidelic response.
This study is aimed to investigate the correlations of impact conditions and dynamic responses with the injuries and injury severity of child pedestrians by accident reconstruction. For this purpose, the pedestrian accident cases were selected from Sweden and Germany with detailed information about injuries, accident cars, and accident environment. The selected accident cases were reconstructed using mathematical models of pedestrian and passenger car. The pedestrian models were generated based on the height, weight, and age of the pedestrian involved in accidents. The car models were built up based on the corresponding accident car. The impact speeds in simulations were defined based on the reported data. The calculated physical quantities were analyzed to find the correlation with injury outcomes registered in the accident database. The reconstruction approaches are discussed in terms of data collection, estimating vehicle impact speeds, pedestrian moving speeds and initial posture, secondary ground impact, validity of the mathematical models, as well as impact biomechanics.
Pelvic fracture, cracking or breaking of a portion of the pelvis are extremely common injuries in the side impact collisions of motor vehicles. Due to both its shape and structural architecture, mechanics of the pelvic bone is complicated. There is a lack of knowledge regarding the dynamic behavior of the pelvis and its biomechanical tolerance under impact environment. Hence this study is aimed at the understanding of the mechanical response of the human pelvis with three-dimensional finite element (FE) models, under side impact load, applied through a structure, equivalent to a car door. The door structure was modeled, considering few layers, consisting of foam (Styrodur®, 3035 CS), plastic (UHMWPE), steel, glass and steel, putting them in series. A soft tissue layer (equivalent to fat) was also considered on the greater trochanter location. These FE models (with and without the car door structure) were analyzed with ANSYS-LS-DYNA-® dynamic finite element software to compare the effect of the car door padding system for shock absorption. It was observed that with proper combination of shock absorbing material (foam, etc.) and its thickness, the transmission of impact load to the body part (pelvis, etc.) from the outer surface of the car door could be reduced.
The use of proper child restraint systems (CRS) is mandatory for children travelling in cars in most countries of the world. The analysis of the quantity of restrained children shows that more than 90% of the children in Germany are restrained. Looking at the quality of the protection, a large discrepancy between restrained and well protected children can be seen. Two out of three children in Germany are not properly restrained. In addition, considerable difference exists with respect to the technical performance of CRS. For that reason investigations and optimisations on two different topics are necessary: The technical improvement of CRS and the ease of use of CRS. Consideration of the knowledge gained by the comparison of different CRS in crash tests would lead to some improvements of the CRS. But improvement of child safety is not only a technical issue. People should use CRS in the correct way. Misuse and incorrect handling could lead to less safety than correct usage of a poor CRS. For that reason new technical issues are necessary to improve the child safety AND the ease of use. Only the combination of both parts can significantly increase child safety. For the assessment of the safety level of common CRS, frontal and lateral sled tests simulating different severity levels were conducted comparing pairs of CRS which were felt to be good and CRS which were felt to be poor. The safety of some CRS is currently at a high level. All well known products were not damaged in the performed tests. The performance of non-branded CRS was mostly worse than that of the well known products. Although the branded child restraint systems already show a high safety level it is still possible to further improve their technical performance as demonstrated with a baby shell and a harness type CRS.
Validation of human pedestrian models using laboratory data as well as accident reconstruction
(2007)
Human pedestrian models have been developed and improved continually. This paper shows the latest stage in development and validation of the multibody pedestrian model released with MADYMO. The biofidelity of the multibody pedestrian model has been verified using a range of full pedestrian-vehicle impact tests with a large range in body sizes (16 male, 2 female, standing height 160-192cm, weight 53.5-90kg). The simulation results were objectively correlated to experimental data. Overall, the model predicted the measured response well. In particular the head impact locations were accurately predicted, indicated by global correlation scores over 90%. The correlation score for the bumper forces and accelerations of various body parts was lower (47-64%), which was largely attributed to the limited information available on the vehicle contact characteristics (stiffness, damping, deformation). Also, the effects of the large range in published leg fracture tolerances on the predicted risk to leg fracture by the pedestrian model were evaluated and compared with experimental results. The validated mid-size male model was scaled to a range of body sizes, including children and a female. Typical applications for the pedestrian models are trend studies to evaluate vehicle front ends and accident reconstructions. Results obtained in several studies show that the pedestrian models match pedestrian throw distances and impact locations observed in real accidents. Larger sets of well documented cases can be used to further validate the models especially for specific populations as for instance children. In addition, these cases will be needed to evaluate the injury predictive capability of human models. Ongoing developments include a so-called facet pedestrian model with a more accurate geometry description and a more humanlike spine and neck and a full FE model allowing more detailed injury analysis.
A legform impactor with biofidelic characteristics (FlexPLI) which is being developed by the Japanese Automobile Research Institute (JARI) is being considered as a test tool for legislation within a proposed Global Technical Regulation on pedestrian protection (UNECE, 2006) and therefore being evaluated by the Technical Evaluation Group (TEG) of GRSP. In previous built levels it already showed good test results on real cars as well as under idealised test conditions but also revealed further need for improvement. A research study at the Federal Highway Research Institute (BASt) deals with the question on how leg injury risks of modern car fronts can be revealed, reflected and assessed by the FlexPLI and how the impactor can be used and implemented as a legislative instrument for the type approval of cars according to current and future legislations on pedestrian protection. The latest impactor built level (GTα ) is being evaluated by a general review and assessment of the certification procedure, the knee joint biofidelity and the currently proposed injury criteria. Furthermore, the usability, robustness and durability as a test tool for legislation is examined and an assessment of leg injuries is made by a series of tests with the FlexPLI on real cars with modern car front shapes as well as under idealised test conditions. Finally, a comparison is made between the FlexPLI and the current european legislation tool, the legform impactor according to EEVC WG 17.
In the EC FP6 Integrated Project Advanced Protection Systems, APROSYS, the first WorldSID small female prototype was developed and evaluated by BASt, FTSS, INRETS, TRL and UPM-INSIA during 2006 and 2007. Results were presented at the ESV 2007 conference (Been et al., 2007). With the prototype dummy scoring a biofidelity rating higher than 6.7 out of 10 according to ISO/TR9790, the results were very promising. Also opportunities for further development were identified by the evaluation group. A revised prototype, Revision1, was subsequently developed in the 2007-2008 period to address comments from the evaluation group. The Revision1 dummy includes changes in the half arms and the suit (anthropometry and arm biomechanics), the thorax and abdomen ribs and sternum (rib durability), the abdomen/lumbar area and the lower legs (mass distribution). Also a two-dimensional chest deflection measurement system was developed to measure deflection in both lateral and anterior-posterior direction to improve oblique thorax loading sensitivity. Two Revision1 prototype dummies have now been evaluated by FTSS, TRL, UPM-INSIA and BASt. The updated prototype dummies were subjected to an extensive matrix of biomechanical tests, such as full body pendulum tests and lateral sled impact tests as specified by Wayne State University, Heidelberg University and Medical College of Wisconsin. The results indicated a significant improvement of dummy biofidelity. The overall dummy biofidelity in the ISO rating system has significantly improved from 6.7 to 7.6 on a scale between 0-10. The small female WorldSID has now obtained the same biofidelity rating as the WorldSID mid size male dummy. Also repeatability improved with respect to the prototype. In conclusion the recommended updates were all executed and all successfully contributed in achieving improved performance of the dummy.
Evaluation of the performance of competitive headforms as test tools for interior headform testing
(2009)
The European Research Project APROSYS has evaluated the interior headform test procedure developed by EEVC WG 13, representing the head contact in the car during a lateral impact. One important aspect within this test procedure was the selection of an appropriate impactor. The WG13 procedure currently uses the Free Motion Headform as used within the FMVSS 201. The ACEA 3.5 kg headform used in Phase 1 of the European Directive and the future European Regulation on Pedestrian Protection is still discussed as a possible alternative. This paper reports work performed by the Federal Highway Research Institute (BASt) as a part of the APROSYS Task 1.1.3. The study compares the two headform impactors according to FMVSS and ACEA, in a series of basic tests in order to evaluate their sensitivity towards different impact angles, impact accuracy, the effect of differences to impactors of the same type and the effects of the repeatability and reproducibility of the test results. The test surface consisted of a steel tube covered with PU foam and PVC, representing the car interior to be tested. Despite of the higher mass of the FMH the HIC values of this impactor were generally lower than those of the ACEA headform. The FMH showed a higher repeatability of test results but a high sensitivity on the angle of roll, the spherical ACEA impactor performed better with regards to the reproducibility. In case of the ACEA impactor-, the angle of roll had no influence.
Mechanical properties of tibial bone at compressive strain rates of 50-200 s-1 are obtained through Split Hopkinson pressure bar. Cylindrical specimens of 12-15 mm diameter and 2-5 mm thickness were used. The Young- moduli are calculated from linear portion of stress-strain curves. For both cortical and cancellous part of the bones, the Young- modulus was found to increase with the increasing strain rates. Also for both cancellous and cortical bones the Young- modulus increases consistently with increase in densities.