Having a look at safety to traffic and the prevention of accidents it can be observed that technical improvements in active safety of vehicles have let to various positive effects in this area. Among other components the tyre-road-contact takes a key role in the development of active safety technologies. All forces in accelerating, breaking and vehicle guidance have to be transmitted through the tyre-road contact area by friction forces. A common way to characterize a friction process is to identify the coefficient of friction μ between two touching materials. Even though there are several approaches to experimentially characterise road surfaces, no standard method exists. In this paper an overview of existing test methods is given. Furthermore the preliminary design of a newly developed portable test device with its possibility to investigate the tyre-road-friction of arbitrary roads or even places of accidents is shown.
Thoracic injuries are one of the main causes of fatally and severely injured casualties in car crashes. Advances in restraint system technology and airbags may be needed to address this problem; however, the crash test dummies available today for studying these injuries have limitations that prevent them from being able to demonstrate the benefits of such innovations. THORAX-FP7 was a collaborative medium scale project under the European Seventh Framework. It focused on the mitigation and prevention of thoracic injuries through an improved understanding of the thoracic injury mechanisms and the implementation of this understanding in an updated design for the thorax-shoulder complex of the THOR dummy. The updated dummy should enable the design and evaluation of advanced restraint systems for a wide variety (gender, age and size) of car occupants. The hardware development involved five steps: 1) Identification of the dominant thoracic injury types from field data, 2) Specification of biomechanical requirements, 3) Identification of injury parameters and necessary instrumentation, 4) Dummy hardware development and 5) Evaluation of the demonstrator dummy. The activities resulted in the definition of new biofidelity and instrumentation requirements for an updated thorax-shoulder complex. Prototype versions were realised and implemented in three THOR dummies for biomechanical evaluation testing. This paper documents the hardware developments and biomechanical evaluation testing carried out.