Sonstige
Filtern
Dokumenttyp
Volltext vorhanden
- nein (14) (entfernen)
Schlagworte
- Dummy (14) (entfernen)
Institut
- Sonstige (14) (entfernen)
A flexible pedestrian legform impactor (FlexPLI) has been evaluated by a Technical Evaluation Group (Flex-TEG) of the Working Party on Passive Safety (GRSP) of the United Nations Economic Commission for Europe (UN-ECE). It will be implemented within phase 2 of the global technical regulation (GTR 9) as well as within a new ECE regulation on pedestrian safety as a test tool for the assessment of lower extremity injuries in lateral vehicle-to-pedestrian accidents (UN-ECE 2010-1, 2010-2 and 2010-3). Due to its biofidelic properties in the knee and tibia section, the FlexPLI is found to having an improved knee and tibia injury assessment ability when being compared to the current legislative test tool, the lower legform impactor developed by the Pedestrian Safety Working Group of the European Enhanced Vehicle-safety Committee (EEVC WG 17). However, due to a lack of biofidelity in terms of kinematics and loadings in the femur part of the FlexPLI, an appropriate assessment of femur injuries is still outstanding. The study described in this paper is aimed to close this gap. Impactor tests with the FlexPLI at different impact heights on three vehicle frontends with Sedan, SUV and FFV shape are performed and compared to tests with a modified FlexPLI with upper body mass. Full scale validation tests using a modified crash test dummy with attached FlexPLI that are carried out for the first time prove the more humanlike responses of the femur section with applied upper body mass. Apart from that they also show that the impact conditions described in the current technical provisions for tests with the FlexPLI don"t necessarily compensate the missing torso mass in terms of knee and tibia loadings either. Therefore it can be concluded that an applied upper body mass will contribute to a more biofidelic overall behavior of the legform and subsequently an improved injury assessment ability of all lower extremity injuries addressed by the FlexPLI. Nevertheless, the validity of the original as well as the modified legform for tests against vehicles with extraordinary high bumpers as well as flat front vehicles still needs to be evaluated in detail. A first clue is given by the application of an additional accelerometer to the legform.
A legform impactor with biofidelic characteristics (FlexPLI) which is being developed by the Japanese Automobile Research Institute (JARI) is being considered as a test tool for legislation within a proposed Global Technical Regulation on pedestrian protection (UNECE, 2006) and therefore being evaluated by the Technical Evaluation Group (TEG) of GRSP. In previous built levels it already showed good test results on real cars as well as under idealised test conditions but also revealed further need for improvement. A research study at the Federal Highway Research Institute (BASt) deals with the question on how leg injury risks of modern car fronts can be revealed, reflected and assessed by the FlexPLI and how the impactor can be used and implemented as a legislative instrument for the type approval of cars according to current and future legislations on pedestrian protection. The latest impactor built level (GTα ) is being evaluated by a general review and assessment of the certification procedure, the knee joint biofidelity and the currently proposed injury criteria. Furthermore, the usability, robustness and durability as a test tool for legislation is examined and an assessment of leg injuries is made by a series of tests with the FlexPLI on real cars with modern car front shapes as well as under idealised test conditions. Finally, a comparison is made between the FlexPLI and the current european legislation tool, the legform impactor according to EEVC WG 17.
According to the German road traffic regulations children up to the age of 12 or a height below 150 cm have to use approved and appropriate child restraint systems (CRS). CRS must be approved according to UN-ECE Regulation No. 44. The regulation classifies CRS in 5 weight categories. The upper weight group is approved for children from 22 to 36 kg. However, studies show that already today many children weigh more than 36 kg although they have not reached a height of 150 cm. Therefore, no ECE R44 approved CRS is available for these overweight children. In conclusion, today's sizes and weights of children are no longer represented by the current version of the ECE R44. The heaviest used dummy (P10) weighs just 32.6 kg and has a height of 137.9 cm. Statistical data of German children show that already 5% of the children at a height of 137.9 cm have a weight above 45.3 kg. Regarding children at a height of 145 cm, the 95th percentile limit is at a weight of 53.3 kg. Based on these data 4 dummies with different heights and weights were defined and produced. Two of them are overweight. Up to now, there is no experience how current child restraint systems perform in a car crash if they are used by children with a weight above 36 kg and a height smaller than 150 cm. In the future, different child restraint systems will be tested with respect to the ECE R44 regulation using these overweight dummies.
The United Nations Economic Commission for Europe Informal Group on GTR No. 7 Phase 2 are working to define a build level for the BioRID II rear impact (whiplash) crash test dummy that ensures repeatable and reproducible performance in a test procedure that has been proposed for future legislation. This includes the specification of dummy hardware, as well as the development of comprehensive certification procedures for the dummy. This study evaluated whether the dummy build level and certification procedures deliver the desired level of repeatability and reproducibility. A custom-designed laboratory seat was made using the seat base, back, and head restraint from a production car seat to ensure a representative interface with the dummy. The seat back was reinforced for use in multiple tests and the recliner mechanism was replaced by an external spring-damper mechanism. A total of 65 tests were performed with 6 BioRID IIg dummies using the draft GTR No.7 sled pulse and seating procedure. All dummies were subject to the build, maintenance, and certification procedures defined by the Informal Group. The test condition was highly repeatable, with a very repeatable pulse, a well-controlled seat back response, and minimal observed degradation of seat foams. The results showed qualitatively reasonable repeatability and reproducibility for the upper torso and head accelerations, as well as for T1 Fx and upper neck Fx. However, reproducibility was not acceptable for T1 and upper neck Fz or for T1 and upper neck My. The Informal Group has not selected injury or seat assessment criteria for use with BioRID II, so it is not known whether these channels would be used in the regulation. However, the ramping-up behavior of the dummy showed poor reproducibility, which would be expected to affect the reproducibility of dummy measurements in general. Pelvis and spine characteristics were found to significantly influence the dummy measurements for which poor reproducibility was observed. It was also observed that the primary neck response in these tests was flexion, not extension. This correlates well with recent findings from Japan and the United States showing a correlation between neck flexion and injury in accident replication simulations and postmortem human subjects (PMHS) studies, respectively. The present certification tests may not adequately control front cervical spine bumper characteristics, which are important for neck flexion response. The certification sled test also does not include the pelvis and so cannot be used to control pelvis response and does not substantially load the lumbar bumpers and so does not control these parts of the dummy. The stiffness of all spine bumpers and of the pelvis flesh should be much more tightly controlled. It is recommended that a method for certifying the front cervical bumpers should be developed. Recommendations are also made for tighter tolerance on the input parameters for the existing certification tests.