The United Nations Economic Commission for Europe Informal Group on GTR No. 7 Phase 2 are working to define a build level for the BioRID II rear impact (whiplash) crash test dummy that ensures repeatable and reproducible performance in a test procedure that has been proposed for future legislation. This includes the specification of dummy hardware, as well as the development of comprehensive certification procedures for the dummy. This study evaluated whether the dummy build level and certification procedures deliver the desired level of repeatability and reproducibility. A custom-designed laboratory seat was made using the seat base, back, and head restraint from a production car seat to ensure a representative interface with the dummy. The seat back was reinforced for use in multiple tests and the recliner mechanism was replaced by an external spring-damper mechanism. A total of 65 tests were performed with 6 BioRID IIg dummies using the draft GTR No.7 sled pulse and seating procedure. All dummies were subject to the build, maintenance, and certification procedures defined by the Informal Group. The test condition was highly repeatable, with a very repeatable pulse, a well-controlled seat back response, and minimal observed degradation of seat foams. The results showed qualitatively reasonable repeatability and reproducibility for the upper torso and head accelerations, as well as for T1 Fx and upper neck Fx. However, reproducibility was not acceptable for T1 and upper neck Fz or for T1 and upper neck My. The Informal Group has not selected injury or seat assessment criteria for use with BioRID II, so it is not known whether these channels would be used in the regulation. However, the ramping-up behavior of the dummy showed poor reproducibility, which would be expected to affect the reproducibility of dummy measurements in general. Pelvis and spine characteristics were found to significantly influence the dummy measurements for which poor reproducibility was observed. It was also observed that the primary neck response in these tests was flexion, not extension. This correlates well with recent findings from Japan and the United States showing a correlation between neck flexion and injury in accident replication simulations and postmortem human subjects (PMHS) studies, respectively. The present certification tests may not adequately control front cervical spine bumper characteristics, which are important for neck flexion response. The certification sled test also does not include the pelvis and so cannot be used to control pelvis response and does not substantially load the lumbar bumpers and so does not control these parts of the dummy. The stiffness of all spine bumpers and of the pelvis flesh should be much more tightly controlled. It is recommended that a method for certifying the front cervical bumpers should be developed. Recommendations are also made for tighter tolerance on the input parameters for the existing certification tests.
Die Griffigkeit ist die maßgebende Größe für die Übertragung der Längs- als auch der Seitenkräfte von Reifen auf die Straßenoberfläche und hat somit einen erheblichen Anteil an der Straßensicherheit. In Deutschland erfolgt die Erfassung der Straßengriffigkeit im Rahmen von Bauverträgen sowie der Zustandserfassung und -bewertung (ZEB) mit dem Seitenkraftmessverfahren (SKM). Mit der Veröffentlichung der TP Griff-StB (SKM) durch die FGSV am 29.4.2008 ist derzeit das aktuellste Dokument für Griffigkeitsmessungen im Rahmen von Bauverträgen sowie der Zustandserfassung und -bewertung von Bundesfernstraßen (ZEB) mit dem Seitenkraftmessverfahren herausgegeben worden. Dieses Dokument löst die TP Griff-StB (SCRIM) mit ihren drei Allgemeinen Rundschreiben ab und fasst die Ergebnisse aus verschiedenen Forschungsprojekten und Erfahrungen aus den regelmäßigen Messungen der Messgerätebetreiber zusammen.