This paper deals with possibilities to update existing road tunnels in order to fulfill up to date requirements regarding structural fire protection. Besides the upgrading of tunnels with structural fire protection systems (like e.g. fire protection sheets) there is also the possibility of numerical investigations. In research projects carried out on behalf of the Federal Highway Research Institute (BASt) numerical investigations for the proof of sufficient structural fire protection have been done for common road tunnel types. Additionally the influence of different fire loads and fire durations on the bearing capacity of the structures have been investigate existing tunnels regarding structural fire protection. The research results have also been the basis for a current update of national standards for tunnel construction.
Immediate user self-evacuation is crucial in case of fire in road tunnels. This study investigated the effects of information with or without additional virtual reality (VR) behavioural training on self-evacuation during a simulated emergency situation in a road tunnel. Forty-three participants were randomly assigned to three groups with accumulating preventive training: The control group only filled in questionnaires, the informed group additionally read an information brochure on tunnel safety, and the VR training group received an additional behavioural training in a VR tunnel scenario. One week later, during the test session, all participants conducted a drive through a real road tunnel in which they were confronted with a collision of two vehicles and intense smoke. The informed and the behaviourally trained participants evacuated themselves more reliably from the tunnel than participants of the control group. Trained participants showed better and faster behavioural responses than informed only participants. Interestingly, the few participants in the control group who reacted adequately to the scenario were all female. A 1 year follow-up online questionnaire showed a decrease of safety knowledge, but still the trained group had somewhat more safety relevant knowledge than the two other groups. Information and especially VR behavioural training both seem promising to foster adequate self-evacuation during crisis situations in tunnels, although long term beneficial behavioural effects have to be demonstrated. Measures aiming to improve users/ behaviour should take individual difference such as gender into account.
Um die Sicherheit der Straßentunnel zu gewährleisten, werden mehr als 400 m lange Tunnel ständig durch eine Tunnelleitzentrale überwacht. Die dort eingehende Flut von Einzelinformationen, wie Kamerabilder und zahlreiche Sensordaten, muss permanent durch das Personal erfasst und beurteilt werden. Das Projekt ESIMAS (Echtzeit-Sicherheits-Management-System für Straßentunnel) wird neue Wege aufzeigen, um die Leitstellenmitarbeiter zu unterstützen. Auf Grundlage der Datenanalyse und -bewertung von ESIMAS können zukünftig sicherheitsrelevante Ereignisse, wie ein Brand im Tunnel, zuverlässig und rechtzeitig erkannt werden. Im Ernstfall soll ESIMAS dem Leitzentralenpersonal sowie den Einsatz- und Rettungsdiensten Handlungsempfehlungen zur Ereignisbewältigung zur Verfügung stellen. Auf Basis dieser Handlungsempfehlungen können Maßnahmen schnellstmöglich und gezielt durchgeführt werden. Der innovative Ansatz von ESIMAS besteht in der ganzheitlichen Betrachtung aller Einzelinformationen und ihrer automatischen Auswertung und Bewertung. Hierdurch ist eine schnellere Reaktion der Leitstelle zum Schutz der Verkehrsteilnehmer möglich.
Die Aufrechterhaltung von Mobilität sowie der Schutz von Mensch und Natur vor den negativen Einwirkungen von Verkehr erfordern effiziente Lösungen zur Bewältigung des zunehmenden Güterfernverkehrs. Eine Möglichkeit zur Bewältigung des langfristig zunehmenden Straßengüterfernverkehrs wird in der Einführung größerer Transportfahrzeuge bzw. geänderter Fahrzeugkombinationen gesehen. Lang-Lkw weisen aufgrund der größeren maximalen Länge von 25,25 m unter Beibehaltung des bisher gültigen Gesamtgewichtes ein im Vergleich zu konventionellen Lkw vergrößertes Ladevolumen auf. Im Rahmen dieses Forschungsvorhabens wurde untersucht, ob aufgrund des Einsatzes von Lang-Lkw erhöhte Anforderungen an die sicherheits- und brandschutztechnische Ausstattung von Straßentunneln zu stellen sind. Auf Basis von Recherchen zu Ladevolumen und -zusammensetzung wurden Brandleistungen und Rauchfreisetzungsraten von Lang-Lkw ermittelt, mit denen anhand von CFD-Simulationen verschiedener Brandszenarien die Berechnung von Rauch- und Temperatureinwirkung auf die Tunnelnutzer durchgeführt wurde. In einer anschließenden quantitativen Sicherheitsbewertung wurden szenarioabhaengig Schadensausmaße und Eintrittshäufigkeiten der Situation eines nach RABT ausgestatteten Tunnels ohne Lang-Lkw-Verkehr vergleichend gegenübergestellt. Ziel dieses Forschungsvorhabens war es, zu überprüfen, ob die bisher festgelegten Brandlasten für Brände in Straßentunneln auch für Lang-Lkw zutreffen. Zudem waren die aus dem Einsatz von Lang-Lkw auf dem deutschen Straßennetz resultierenden Sicherheitsrisiken für Straßentunnel, insbesondere im Brandfall, zu identifizieren, zu quantifizieren und zu beurteilen. Die Auswirkungen von Fahrzeugbränden mit Lang-Lkw auf die Sicherheit der Tunnelnutzer wurden analysiert, um ggf. erhöhte sicherheitstechnische und brandschutztechnische Anforderungen an Straßentunnel abzuleiten. Die Ergebnisse und ihre Beurteilung wurden abschließend als Empfehlungen an Entscheidungsträger formuliert.
Aufgrund der sich weiter verschärfenden EU-Abgasvorschriften werden sich Auswirkungen auf die betriebstechnische Ausrüstung von Straßentunneln ergeben. Dies gilt insbesondere für die Lüftungsanlagen. Die derzeit gültigen Richtlinien für die Ausstattung und den Betrieb von Straßentunneln (RABT) aus dem Jahre 1994 müssen aufgrund der Ergebnisse neuerer Untersuchungen und der neuen EU-Vorschriften überprüft werden. Wegen des starken Rückganges der CO-Emissionen und des zur Sichttrübung führenden Partikelausstoßes von Dieselfahrzeugen wird für den Betriebsfall ein wesentlich geringerer Frischluftbedarf zu erwarten sein. Zur Bewertung der zu erwartenden Sichttrübung müssen künftig aber bisher vernachlässigbare Einflüsse aus Abrieb von Reifen, Straße und Bremsbelägen sowie Sprühnebel und Staub berücksichtigt werden. Unabhängig vom Regelbetrieb wird aber die Tunnellüftung auch auf einen möglichen Brandfall zu bemessen sein. Zur Klärung der noch offenen Fragen werden weitere Forschungsarbeiten als notwendig erachtet.
Although the bus belongs to the safest traffic means, single accidents can be particularly severe and concern many passengers. Especially in case of fires a high number of injured and killed persons can be the outcome. Fire safety of buses therefore is of high importance. With the increase of plastic materials as a material for the interior equipment of buses and coaches due to their good mechanical properties combined with low weight, the question arises whether the safety level has decreased in case of a fire during the last years " also compared to other means of transport. Because of the combustible plastics and their ability to release a high amount of heat the main fire load in buses is no longer the fuel but the plastic materials which are also often easy to ignite. Besides the flammability of the equipments, also the production of smoke, the smoke development and propagation as well as its toxicity are of interest. That counts for the passengers as well as for the test methods and its limit values. The severe fire in Germany near Hanover in 2008 with 20 fatalities showed how disastrous such fires can be. For those reasons several research projects were initiated on behalf of the German Federal Highway Research Institute. At the one hand the fire behaviour of coach interiors was examined in general focusing on fire propagation as well as fire detection and signalling. As result, recommendations with regard to early fire detection systems for the engine compartments and onboard extinguishing equipment were elaborated. On the other hand research was carried out to examine heat release, smoke, smoke propagation and its toxicity due to burning bus interior materials. In this project small and real scale experiments on material specimens, interior parts and vehicles were performed. Trains and buses often have very similar operation conditions. Consequently, bus interior material was tested according to the regulations for rail vehicles, i.e. DIN EN 45545 as well as DIN 5510. None of the tested bus interior materials would have been allowed to use in a train. The fire safety regulations for bus materials are on a low level compared to other transport sectors, i.e. railway, ship and aircraft. Also numerical investigations with the Fire Dynamics Simulator (FDS) were performed. The very rapid fire development during the severe bus fire from 2008 could be predicted with the numerical model. The model was then used to investigate the influence of different materials, ventilation conditions and ignition sources. The bus materials contribute significantly to a very rapid fire development in bus fires. Especially, the flammable ceiling and the passenger seats were identified to be key issues of the fire propagation in a bus and can be explained by the rapid fire spread along the ceiling and the high fire load of passenger seats. As conclusion of the project effective and economically reasonable fire safety requirements for interiors of buses are recommended which would improve the current situation. Proposals for amendments of current requirements are recommended including the specification of appropriate limit values. In particular, it is taken into consideration which reasonable fire safety standards from other transport sectors, especially the rail sector, should be transferred to buses
Although the bus belongs to the safest traffic means, single accidents can be particularly severe and concern many passengers. Especially in case of fires a high number of injured and killed persons can be the outcome. Fire safety of buses therefore is of high importance. With the increase of synthetic and plastic materials as a material for the interior equipment of buses and coaches because of their ood mechanical properties combined with low weight, the question arises whether the safety level has decreased in case of a fire during the last years - also compared to other means of transport. Because of the combustible plastics and their ability to release a high amount of heat the main fire load in buses is no longer the fuel but the plastic materials which are also often easy to ignite. Besides the flammability of the equipments, the production of smoke, the smoke development and propagation and its toxicity for the people as well as the testing methods and limit values are of interest. For those reasons research projects were initiated on behalf of the German Federal Highway Research Institute. At the one hand the fire behavior of coach interiors was examined in general focusing on fire propagation as well as fire detection and signalling. As result, recommendations with regard to early fire detection systems for the engine compartments and on-board extinguishing equipment were elaborated. At the other hand research is carried out to examine heat release, smoke, smoke propagation and its toxicity due to burning bus interior materials. The paper describes which effective and economically reasonable fire safety requirements for interiors of buses would improve the current situation. Proposals for amendments of current requirements are recommended including the specification of appropriate limit values. In particular, it is taken into consideration which reasonable fire safety standards from other transport sectors, especially the rail sector, should be transferred to buses.
In dem geltenden Regelwerk für Straßentunnel, der ZTV-ING, ist das derzeitige rechnerische Nachweisverfahren zum baulichen Brandschutz für Rechteckrahmenquerschnitte im Teil 5, Abschnitt 2 über ein vereinfachtes Nachweisverfahren mit Ansatz eines Temperaturgradienten von 50 K in Wand und Decke geregelt. Alternativ kann nach ZTV-ING ein "genauerer" rechnerischer Nachweis durchgeführt werden, der jedoch in der Praxis kaum angewendet wird, da hierzu bisher keine eindeutigen Regelungen zur Durchführung vorliegen. Es stellen sich insbesondere die Fragen, inwieweit über einen genaueren rechnerischen Nachweis Einsparpotenziale bei der Bewehrung gegenüber dem vereinfachten Nachweis vorliegen und welchen Einfluss eine verlängerte ZTV-ING-Kurve (55 Minuten Vollbrandphase statt 25 Minuten Vollbrandphase) auf die erforderlichen Bewehrungsgehalte hat. Im vorliegenden Forschungsvorhaben wurden die genaueren rechnerischen Nachweise für typische Rechteckrahmenquerschnitte von Straßentunneln (ein- und zweizellig) auf Grundlage des Eurocodes EN 1992-1-2 [4], "Allgemeines Rechenverfahren", durchgeführt. Aufgrund des deutlich unterschiedlichen Abplatzverhaltens von Beton ohne PP-Fasern und Beton mit PP-Fasern mit entsprechendem Einfluss auf das Tragverhalten im Brandfall wurden differenzierte Berechnungen durchgeführt. Die Annahmen für die Größe und den Zeitpunkt der Betonabplatzungen basieren auf den Auswertungen von Großbrandversuchen für Rechteckrahmen [10]. In zusätzlichen statischen Berechnungen wurde der Lastfall nach dem Brand mit Berücksichtigung der veränderten Baustoffeigenschaften durch die Brandeinwirkung nachgewiesen. Auf Grundlage der durchgeführten Berechnungen wurde ein Leitfaden mit Musterstatik für den genaueren rechnerischen Brandschutznachweis erstellt. Der Leitfaden mit Musterstatik soll bei der zukünftigen Dimensionierung von Rechteckkonstruktionen von Straßentunneln einen optimierten Brandschutznachweis mit einhergehenden Kostenoptimierungen gegenüber dem bisherigen vereinfachten Brandschutznachweis ermöglichen. Es hat sich gezeigt, dass der genaue rechnerische Nachweis des Brandfalls ein komplexes Berechnungsverfahren ist, das in der Praxis noch nicht erprobt ist. Auf Grundlage der Ergebnisse des genaueren rechnerischen Nachweisverfahrens wurde ein für die Praxis zweckmäßiges Berechnungsverfahren mit Vorgabe eines von der Bauteildicke abhängigen linearen Temperaturgradienten entwickelt. Voraussetzung für die Anwendung dieses Nachweisverfahrens sind vergleichbare Randbedingungen im Brandfall hinsichtlich Größe von Betonabplatzungen und Temperaturverteilungen im Bauteil, welche bei der Verwendung von Betonen mit PP-Fasern und entsprechenden Vorgaben an Rezeptur, Herstellung und Verarbeitung gesehen werden. Für eine Fortschreibung der ZTV-ING, Teil 5, Abschnitt 2, Nr. 10 "Baulicher Brandschutz" werden entsprechende Empfehlungen formuliert.
An analysis of NASS and FARS was conducted to determine crash conditions that involved injuries that are not currently being directly addressed by vehicle safety standards or by consumer information test protocols. Analysis of both field data and US NCAP tests were conducted to determine the relative safety provided by seating position and by vehicle model year. Opportunities for improvements were determined by crash categories with large populations of injuries that were not addressed by safety tests or smaller numbers that were increasing in frequency. Areas of opportunities include improved occupant restrain in rollovers, improved frontal protection for rear seat occupants and improved fire prevention in frontal and rollover crashes.
In der jüngeren Vergangenheit hat sich gezeigt, dass Straßentunnel durch größere Brände in erheblichem Umfang geschädigt werden können. In der Folge wurden verschiedene internationale Forschungsprojekte durchgeführt, um den baulichen Brandschutz von Straßentunneln weiterzuentwickeln. Aufbauend auf den internationalen Forschungsprojekten wurden vom BMVBS und der BASt drei nationale Forschungsprojekte zum baulichen Brandschutz von Straßentunneln initiiert. In diesen Projekten wurden vorhandene Temperatur-Zeit-Verläufe (sog. "Brandkurven") für Straßentunnel, Brandversuche in Tunneln und reale Brände in Straßentunneln im Hinblick auf eine mögliche Anwendung zur Bemessung des baulichen Brandschutzes von Straßentunneln analysiert. Außerdem wurden die Temperatureindringung in die Tunnelinnenschale und die Tragfähigkeit von üblichen Tunnelquerschnitten infolge Brandeinwirkung numerisch ermittelt. Schließlich wurde anhand von Brandversuchen an großmaßstäblichen Probekörpern die Wirkung von PP-Faserbeton auf das Abplatzverhalten von Innenschalenbeton untersucht. Über das Vorgehen und die Ergebnisse dieser Forschungsprojekte wird im Folgenden berichtet.