Knowledge of material properties is of great importance when developing new types of concrete and construction methods for road building, and for quality control and quality assurance. Physical material characteristics are likewise the basis for dimensioning and assessing the residual substance of concrete pavements. One relevant characteristic when examining thermally induced stress and deformation is the coefficient of thermal expansion (CTE) of concrete. This indicator, for example, significantly influences the longitudinal expansion of the pavement system as well as the degree of curling of slabs and joint movements. Extensive tests were conducted during the technical engineering assessment of the structural substance of concrete pavements in the German motorway network, including tests to determine the CTE of existing types of concrete. Because no standardised procedure currently exists in Germany for using tests to determine the CTE of concrete, the initial task was to develop a suitable test procedure from a road-building perspective, taking consideration of the national prevailing structural conditions. This article presents the results of selected status analyses, in which the CTE was determined for a total of 656 individual samples. The values calculated for the top and bottom drilled core layer are in the range 8.9 – 13.2 x 10-6/K, whereby the average CTE assumes a value of 10.7 x 10-6/K. The deviations of the CTEs from the bottom and top drilled core layer are in principle significantly below the limitation to a maximum of 2.50 x 10-6/K recommended in literature.
Reduzierung der Schwindverformungen des Straßenbetons durch den Einsatz neuartiger Schwindreduzierer
(2019)
Fahrbahndecken aus Beton werden neben den Verkehrslasten auch durch lastunabhängige Einwirkungen beansprucht. Hierzu zählen neben den thermischen Verformungen vor allem Schwindverformungen. Überschreiten die resultierenden Zwangsspannungen die Zugfestigkeit des Betons, kann es zu einer Rissbildung kommen. Daher werden i. d. R. in einem Abstand von rd. 5 m Fugen angeordnet, welche die Zwangsspannungen wirksam reduzieren. Zur Reduktion von Zwangsspannungen infolge Schwindverformungen stehen seit geraumer Zeit sog. Schwindreduzierer (SRA) zur Verfügung, durch die sowohl die Schwindverformungen im jungen Alter als auch das Trocknungsschwinden vermindert werden können. Ziel war es, zu eruieren, inwieweit durch SRA Schwindverformungen und damit potenzielle Risse effektiv vermindert werden können. Dazu waren insbesondere Schwinduntersuchungen sowohl im frischen / erhärtenden Beton als auch im späteren Alter am erhärteten Beton durchzuführen. Daneben war auch zu untersuchen, inwieweit die Frisch- und Festbetoneigenschaften potenziell beeinflusst werden. Mit den Untersuchungen konnte gezeigt werden, dass SRA insbesondere die sich frühzeitig einstellenden Schwindverformungen reduzieren können. Besonders positiv wirkt sich dies auf die Vermeidung von Frühschwindrissen in den ersten Tagen aus. Die Schwindreduzierung war generell in der Anfangsphase stets größer und nahm nach 187 Tagen auf Werte zwischen 30 bis 50 % ab. Inwieweit das über Jahre ablaufende Trocknungsschwinden reduziert wird, kann aus diesen bis lediglich 6 Monate umfassenden Untersuchungen nicht abgeleitet werden. Die Frischbetoneigenschaften wurden durch die SRA nicht beeinflusst. Ebenso zeigten sich keine nennenswerten Änderungen in der Druckfestigkeit, der Spaltzugfestigkeit und im statischen Elastizitätsmodul. Hingegen zeigte sich, dass das Mikroluftporensystem in Betonen mit hohem Frost-Taumittelwiderstand durch die Zugabe von SRA auf Basis von Glykol und Polyglykol nachteilig beeinflusst werden kann.
Im Rahmen des Konjunktur-Pakets II beteiligt sich der Bund mit Finanzhilfen an der Lärmsanierung kommunaler Straßen. Grundlagen für die Förderung ist das "Gesetz zur Umsetzung von Zukunftsinvestitionen der Kommunen und Länder". Nach diesem Gesetz werden Investitionen im Bereich der kommunalen Straßen ausdrücklich auf Maßnahmen des Lärmschutzes beschränkt. In jedem Einzelfall muss die Lärmsituation verbessert werden und diese Verbesserung möglichst konkret dargelegt werden. Problematisch ist aber, dass es derzeit keine Straßenoberflächen gibt, denen eine lärmmindernde Wirkung bei innerorts üblichen Geschwindigkeiten zugewiesen ist. Geeignete Messverfahren zur Bestimmung der Minderungspegel stehen bereits zur Verfügung. An Verfahren zur Bewertung und Klassifizierung von Straßenoberflächen wird derzeit noch gearbeitet. Gleichwohl sind bereits vielversprechende Straßenoberflächen bekannt, die vermutlich als lärmarm (Minderung mindestens 2 dB(A)) klassifiziert werden können, wenn ein umfangreiches Messprogramm die Klassifizierung dieser Beläge rechtfertigt. Die RLS-90 werden derzeit überarbeitet. Insbesondere die Emissionsannahmen sind nach fast 20 Jahren veraltet und bedürfen einer Aktualisierung. Um zukünftigen Entwicklungen bei der Geräuschemission Rechnung tragen zu können, soll in den neuen RLS statt auf eine Tabelle mit Korrekturwerten DStrO auf ein Verfahren verwiesen werden, mit dem neue Werte ermittelt werden können. Dabei sollte auch eine Aufteilung nach Motor- und Antriebsgeräusch bzw. Reifen-Fahrbahn-Geräusch sowohl von Pkw als auch von Lkw vorgenommen werden.
As investigations by BASt have shown, a bond between concrete surfaces and bases may be a disadvantage when water penetrates via joints and from the sides if the bond becomes partially detached at an early stage. Free water may penetrate into the area between the concrete surface and the base and build up in areas where the bond is still intact. The high pressure caused by lorry wheels rolling over the pavement causes hydrodynamic pumping. This creates very high flow speeds with considerable corrosion power. This results in the base course surface being eroded in the areas where heavy vehicles drive over the road and may even lead to water and fine particles from the base courses being expelled through the longitudinal joints between the pavement slab and the lower hard shoulder or first overtaking lane. The erosion of the base leads unavoidably to the bearing conditions deteriorating and increased loading of the concrete surface. Cracks may occur and, later stepping-off and tilting of the plates components. This significantly deteriorates the evenness and consequently the service value of the road. This finally leads to a reduction in the service life of the concrete surface. To avoid such damage water which has penetrated must be able to lose pressure and to then seep away. A possible solution is: A nonwoven fabric substance between concrete suface and bound base course. This construction method has proved himselve on numerous test road sections and were rightly included in the new Codes of Practice for the Standardisation of the Upper Structure of Traffic-Bearing Surfaces (Richtlinien für die Standardisierung des Oberbaues von Verkehrsflächen- RStO).
Für die Herstellung von Betonfahrbahndecken ist für Ober- und Unterbeton ein Zement der gleichen Art und Festigkeitsklasse zu verwenden. Durch eine flexiblere Handhabung von Bindemitteln im Ober- und Unterbeton können sich ökologische und wirtschaftliche Vorteile eröffnen. Ein sinnvoller Ansatz ist die Verwendung von Zementen mit hohem Klinkeranteil für den hochbelasteten, dünnen Oberbeton in Verbindung mit Zementen mit reduziertem Klinkeranteil für den Unterbeton. So kann die Ökobilanz der Betonstraße verbessert und die Gefahr einer schädigenden Alkali-Kieselsäure-Reaktion (AKR) im Unterbeton vermindert werden. Vorteile können sich ebenfalls aus einem teilweisen Zementersatz durch Steinkohlenflugasche im Ober- sowie Unterbeton ergeben. Da die Anrechnung der Flugasche auf den Wasser/Zement-Wert des Fahrbahndeckenbetons nicht gestattet ist, wird Flugasche in der Regel nicht für den Bau von Verkehrsflächen aus Beton verwendet. Im Rahmen des Forschungsvorhabens sollten die notwendigen betontechnologischen Kenntnisse gewonnen werden, um eine kritische Bewertung der genannten Einschränkungen in der Bindemittelanwendung im Betonstraßenbau vornehmen zu können. Im Ergebnis wurde eine Modifizierung der Einschränkungen angestrebt. Es galt nachzuweisen, dass sich unter den spezifischen Randbedingungen von Fahrbahndecken aus Beton weder für Herstellung, Nutzung sowie Dauerhaftigkeit (insbesondere Frost-Taumitteleinwirkung) Nachteile oder Beeinträchtigungen ergeben. Insbesondere war dabei das Verbund- und Verformungsverhalten von Ober- und Unterbeton zu berücksichtigen. Weiterhin wurde untersucht, inwiefern durch die Verwendung von hüttensandhaltigen Zementen bzw. von Flugasche im Unterbeton das Risiko einer AKR vermindert wird und dadurch die Anzahl an verwendbaren Gesteinskörnungen im Unterbeton vergrößert werden kann. Aus labortechnischer Sicht sowie auf Basis theoretischer Betrachtungen wurden die angestrebten Vorteile der Verwendung unterschiedlicher Bindemittel in Ober- und Unterbeton bei vertretbaren technologischen Risiken erzielt. Insbesondere das AKR-Schadenspotential ausgewählter kritischer Gesteinskörnungen konnte durch Einsatz hüttensandhaltiger Zemente sowie auch durch Steinkohlenflugasche deutlich gesenkt werden. Die Anrechnung von Steinkohlenflugasche auf w/z-Wert und Zementgehalt verursachte in Verbindung mit klinkerreichen Zementen (bis 15 % HÜS) keine nennenswerte Verminderung des Frost-Tausalz-Widerstandes. Auf Grundlage der gewonnenen Erkenntnisse kann die Beachtung der aufgezeigten Ansätze im Regelwerk empfohlen werden. Eine baupraktische Bestätigung dieser Ergebnisse, z. B. in Form einer Probestrecke ist zu empfehlen.
Bewertung der strukturellen Substanz für die systematische Erhaltungsplanung von Betonfahrbahndecken
(2016)
"Mobilität ist zentrale Voraussetzung für wirtschaftliches Wachstum, Beschäftigung und Teilhabe des Einzelnen am gesellschaftlichen Leben." Dieser Leitsatz des BMVI setzt eine intakte und funktionierende Infrastruktur voraus. Im Kontext mit dem Investitionshochlauf in den nächsten Jahren ist für das Bundesfernstraßennetz insbesondere ein netzbezogenes systematisches Vorgehen im Rahmen der Baulichen Erhaltung von Relevanz. Bei der Planung von Erneuerungsmaßnahmen ist dabei die Kenntnis über den Zustand der strukturellen Substanz und deren langfristige Entwicklung von zentraler Bedeutung. Nachfolgend wird ein Verfahren vorgestellt, das die mechanisch und statistisch abgesicherte Bewertung und Prognose der strukturellen Substanz von Betonfahrbahndecken ermöglicht. Zudem werden die Anwendung und das Vorgehen anhand eines Praxisbeispiels aufgezeigt.
Bau und Messungen an einer Versuchsstrecke mit optimierter Kiestragschicht unter der Betondecke
(2018)
Im Rahmen des Forschungsvorhabens wurde ein bereits unter Laborbedingungen bewährtes Baustoffgemisch 0/32 mm " bestehend aus gebrochenen und ungebrochenen Gesteinskörnungen - für die Herstellung einer modifizierten Kiestragschicht unter einem Betonfahrbahndeckensystem einer realen Versuchstrecke verwendet. Die messtechnische Begleitung dieses Versuchsstreckenbaus an einer Fahrgasse der Tank- und Rastanlage Köschinger Forst (BAB 9) im Sommer / Herbst 2012 umfasste unter anderem umfangreiche Tragfähigkeitsmessungen auf den einzelnen ungebundenen Schichten des Oberbaus. Die 30 cm dicke modifizierte Kiestragschicht wurde mit einer 27 cm dicken unbewehrten Betonfahrbahndecke in Plattenbauweise überbaut. Die Tragfähigkeitsmessungen auf der modifizierten Kiestragschicht wurden unmittelbar nach dem Einbau und nach 16 Tagen unter freier Witterung und Baustellenverkehr durchgeführt. Bei allen Messungen wurden die Vorgaben der ZTV SoB-StB " Ev2 ≥ 150 MPa " erfüllt. Eine Fuge der Fahrgasse wurde unverdübelt und ohne Fugenmasse ausgeführt, um durch die erhöhten Relativbewegungen der Plattenränder und den gleichzeitigen hohen Wassereintrag eine Erosion der Tragschicht im Fugenbereich zu induzieren. Im Mai 2015 erfolgten - nach 32-monatiger Liegedauer - die Wiederholungsmessungen. Die Überrollungen der unverdübelten Querscheinfuge konnten zum damaligen Zeitpunkt grob mit 350.000 Fahrzeugen (ca. 1 Mio. äquivalente 10t-Achsen) abgeschätzt werden. Für die Wiederholungsmessungen wurden zwei Einzelfahrbahnplatten der Lkw-Fahrgasse abgehoben. Es konnten hierbei keine wesentlichen Veränderungen der für eine KTSuB relevanten Performanceparameter festgestellt werden. Die in den ZTV SoB-StB und den RStO geforderten Mindestwerte der Tragfähigkeit - statischer Verformungsmodul und Verhältniswert Ev2/Ev1 - konnten an allen untersuchten Prüfpunkten eingehalten werden. Des Weiteren konnten die Bedenken hinsichtlich der Erosions- und Umlagerungsbeständigkeit im Fugenbereich beim vorliegenden - relativ langsam fahrenden Schwerlastverkehr - relativiert werden.
Zerstörungsfreie Prüfverfahren (ZfP) zur Messung der Betondeckung sind seit Jahrzehnten bei der Ermittlung des Istzustands von Bestandsbauwerken und als Werkzeug zur Qualitätssicherung sowohl im Neubau als auch in der Betoninstandsetzung fest etabliert. Um zuverlässige Prüfaussagen zu erhalten, ist es zunächst erforderlich, durch die richtige Anwendung eines geeigneten Verfahrens genaue Messergebnisse zu erzeugen und diese dann richtig zu bewerten, z. B. durch einen statistischen Nachweis der Mindestbetondeckung. Daher konzentriert sich dieser Beitrag zunächst auf die Grundlagen von ZfPBauâ€Verfahren zur präzisen Messung der Betondeckung. Hierbei sind magnetisch induktive Verfahren von radarbasierten Verfahren zu unterscheiden, deren jeweilige Möglichkeiten und Grenzen dargelegt werden. Im zweiten Teil wird die erzielbare Genauigkeit mit unterschiedlichen Geräten nach magnetisch induktivem Messprinzip anhand von systematischen Untersuchungen betrachtet. Dabei wird quantifiziert, mit welchen Abweichungen zu rechnen ist, wenn der Durchmesser nicht genau bekannt ist und dicht benachbarte Stäbe das Messergebnis beeinflussen. Abschließend werden die verminderten Abweichungen quantifiziert, wenn geräteeigene Nachbarstabskorrekturen verwendet werden. Das Ziel dieses Beitrags ist kein "Gerätetest", vielmehr soll am Beispiel verschiedener Geräte auf der Basis unterschiedlicher Messprinzipien gezeigt werden, welche Genauigkeit unter welchen Einflussgrößen bei realen Messungen zu erzielen ist.
Im Dezember 2015 wurde die A1-Änderung zum deutschen Nationalen Anhang von DIN EN 1992-1-1 veröffentlicht. Die Änderungen betreffen u. a. den Ansatz der wirksamen Betonzugfestigkeit bei der Ermittlung der Mindestbewehrung zur Begrenzung der Rissbreiten bei frühem Zwang. Der nachfolgende Beitrag erläutert die Hintergründe, warum eine entsprechende A1-Änderung zu DIN EN 1992-2/NA nicht erfolgt. Als Begründung für diese unterschiedliche Vorgehensweise werden die wesentlichen Unterschiede zwischen dem Hochbau und dem Brückenbau dargestellt.
Steigende Beanspruchungen insbesondere durch Schwerlastverkehr und altersbedingte Tragfähigkeitsdefizite älterer Brückenbauwerke führen dazu, dass zahlreiche Betonbrücken instand gesetzt oder verstärkt werden müssen. Um einen Beitrag zur konstruktiv und wirtschaftlich erfolgreichen Durchführung zukünftiger Verstärkungsmaßnahmen zu leisten, wurde im Auftrag der Bundesanstalt für Straßenwesen (BASt) eine Erfahrungssammlung zu "Verstärkungen älterer Beton†und Spannbetonbrücken" erstellt. In der Dokumentation wird ein Überblick über den Stand der Technik der im Massivbrückenbau eingesetzten Verstärkungstechniken gegeben, und insgesamt 76 durchgeführte Verstärkungsmaßnahmen werden ausgewertet. Repräsentative Verstärkungsmaßnahmen werden in anonymisierter Form detailliert vorgestellt. Der vorliegende Bericht gibt einen Überblick über die in Kürze erscheinende Erfahrungssammlung, wobei die wesentlichen Erfahrungen der ausgewerteten Anwendungsfälle vorgestellt werden.
The current maintenance management for bridges is mainly based on visual inspection and aims at the repair of identified damages. In the project cluster "Smart Bridge" an adaptive system for holistic evaluation in real time is developed. The following pilot studies show significant aspects of the Smart Bridge. Within the research project "Digital Test Area Autobahn" a new constructed prestressed concrete bridge is implemented with instrumented expansion joints and bearings, a "RTMS©" and a sensor network. By using analytical bridge models and evaluation methods the condition and reliability of the bridge as well as the remaining service life is determined. In the pilot study "duraBASt" sensors for the detection of durability and structural safety as well as data analyzing and evaluation procedures are investigated. The aim of this study is the partial implementation of the aspects: data collection, data processing and model development for condition assessment of the bridge.
Bewertung der strukturellen Substanz für die systematische Erhaltungsplanung von Betonfahrbahndecken
(2017)
"Mobilität ist die zentrale Vorrausetzung für wirtschaftliches Wachstum, Beschäftigung und Teilhabe des Einzelnen am gesellschaftlichen Leben". Dieser Leitsatz des BMVI setzt eine intakte und funktionierende Infrastruktur voraus. Im Kontext mit dem Investitionshochlauf in den nächsten Jahren ist das Bundesfernstraßennetz insbesondere ein netzbezogenes systematisches Vorgehen im Rahmen der Baulichen Erhaltung von Relevanz. Bei der Planung von Erneuerungsmaßnahmen ist dabei die Kenntnis über den Zustand der strukturellen Substanz und deren langfristige Entwicklung von zentraler Bedeutung. Nachfolgend wird ein Verfahren vorgestellt, das die mechanisch und statisch abgesicherte Bewertung und Prognose der strukturellen Substanz von Betonfahrbahndecken ermöglicht. Zudem werden die Anwendung und das Vorgehen anhand eines Praxisbeispiels aufgezeigt.
Die Wirksamkeit von Beton unter Zugabe von Polypropylen-Fasern (PP-Fasern) als vorbeugende bauliche Brandschutzmaßnahme für Tunnelinnenschalen wurde bereits in vielen Großbrandversuchen im In- und Ausland nachgewiesen. Die spezifischen Anforderungen an den PP-Faserbeton für Straßentunnel in Deutschland bedingen eine besondere Betonzusammensetzung sowie Sorgfalt bei der Herstellung und Verarbeitung des Betons, die im Rahmen eines Forschungsvorhabens unter Laborbedingungen bereits erfolgreich umgesetzt werden konnten. Die Anwendbarkeit von PP-Faserbeton unter Praxisbedingungen wurde nachfolgend beim Tunnel Westtangente Bautzen (B96) in offener Bauweise nachgewiesen. Im vorliegenden Beitrag werden die Ergebnisse dieser erfolgreichen Pilotanwendung dargestellt. Insbesondere wird auf die Erfahrungen mit der Herstellung und Verarbeitung des PP-Faserbetons sowie die durchgeführten Qualitätssicherungsmaßnahmen eingegangen.
Die ZTV-ING, Teil 3, Abschnitt 4 "Schutz und Instandsetzung von Betonbauteilen" beinhaltet technische und vertragliche Regelungen für Erhaltungsmaßnahmen, mit denen positive Erfahrungen in den Straßenbauverwaltungen gesammelt wurden. Grundsätzlich wird Kompatibilität zur Richtlinie des Deutschen Ausschusses für Stahlbeton (DAfStb) "Schutz und Instandsetzung von Betonbauteilen", zur DIN EN 1504 "Produkte und Systeme für den Schutz und die Instandsetzung von Betontragwerken" und ihren nationalen Anwendungsdokumenten angestrebt. Im Bericht wird erläutert, welche Schritte für den Schutz und die Instandsetzung von Betonbauteilen im Regelungsbereich der ZTV-ING erforderlich sind und wie das Regelwerk im Zuge der europäischen Harmonisierung weiterentwickelt wird.
Viele ältere Betonbrücken im Zuge der Bundesfernstraßen müssen wegen massiver Schäden in den nächsten Jahren instandgesetzt, verstärkt oder ersetzt werden. Angesichts dieser Herausforderungen an die Straßenbauverwaltungen und der damit verbundenen Minimierung der Kosten kommt der zielgerichteten Auswahl geeigneter Verstärkungstechniken besondere Bedeutung zu. Die Bundesanstalt für Straßenwesen (BASt) hat daher die Erfahrungssammlung "Verstärkung älterer Beton- und Spannbetonbrücken" in Auftrag gegeben. Es wird ein Überlick über die Erfahrungssammlung (siehe AN 01596101) gegeben. In der Dokumentation wird der Stand der Technik der im Massivbrückenbau eingesetzten Verstärkungsmaßnahmen auf der Grundlage von 76 Anwendungsfällen gegeben. Außerdem werden repräsentative Verstärkungsmaßnahmen in anonymisierter Form detailliert beschrieben. Unter dem Oberbegriff "Verstärkungsmaßnahmen" sind Methoden zur Wiederherstellung oder Erhöhung der Tragfähigkeit oder Gebrauchstauglichkeit zu verstehen, während die unterschiedlichen technischen Lösungen zur Umsetzung dieser Maßnahmen als "Verstärkungstechniken" bezeichnet werden. Eine Ertüchtigung liegt dann vor, wenn man die Tragfähigkeit über den Ursprungszustand hinaus steigert. Zu den beschriebenen Verstärkungstechniken zählen: zusätzliche Vorspannung, Querkraftverstärkung mit Stabspanngliedern oder Schublaschen aus Stahl, schubfest aufgeklebte, in Schlitze eingeklebte oder vorgespannte CFK-Lamellen und aufgeklebte Stahllaschen. Verstärkungstechniken sind auch Querschnittsergänzungen mit verdübeltem Beton, mit Zusatzbewehrungen in Nuten oder zusätzlicher Betonstahlbewehrung. Ebenso zählen dazu Querschnittsergänzungen durch Spritzbeton mit zusätzlicher Betonstahlbewehrung. Einige dieser Verstärkungstechniken werden detailliert beschrieben. Des Weiteren wird zu 34 repräsentativen Maßnahmen ein Überblick gegeben. Als Erweiterung der Zusätzlichen Technischen Vertragsbestimmungen und Richtlinien für Ingenieurbauwerke (ZTV-ING) wurde auf der Basis der Erfahrungssammlung ein Regelwerkentwurf zum Verstärken von Betonbauteilen erstellt.
Ziel des Forschungsprojektes war, "Schutzmaßnahmen gegen Graffiti" für die Betonflächen der Bauwerke im Zuge der Bundesverkehrswege zu erarbeiten. Anti-Graffiti-Systeme (AGS) bestehen aus den beiden Komponenten Graffitiprophylaxe und Reinigungstechnologie. Graffitiprophylaxen sind flüssige Produkte, die nach der Applikation auf der Bauwerksoberfläche eine Trennschicht ausbilden und dadurch das Eindringen der Graffitifarbmittel in die Bauwerksoberfläche verhindern. Mit der systemzugehörigen Reinigungstechnologie können die Graffiti oberflächenschonend entfernt werden. Zur Klassifizierung der AGS haben sich auf dem Markt drei AGS-Klassen mit den Bezeichnungen permanente, semipermanente und temporäre AGS durchgesetzt. Die AGS werden nach dem "Regelwerk für die Bewertung von Verfahren, Technologien und Materialien zur Graffitientfernung und Graffitiprophylaxe - Teil C (Juli 2000)" der Gütegemeinschaft Anti-Graffiti e.V. geprüft. Die Auswertungen der AGS-Prüfberichte haben ergeben, dass kein AGS eine vollständige Funktionalität aufweisen kann, das heisst, dass nicht alle Farbmittel rückstandsfrei mit der systemzugehörigen Reinigungstechnologie entfernt werden können. Die permanenten AGS zeigen insbesondere nach Bewitterung die höchste Funktionalität. Die niedrigste Funktionalität zeigen die temporären AGS. Erfüllen die AGS die definierten verkehrsbauwerksspezifischen Anforderungen, werden sie für die Anwendung zugelassen und bei der BASt im "Verzeichnis der geprüften AGS für die Anwendung auf Betonflächen" geführt. An Bauwerken im Bundesfernstraßenbereich sind ausschließlich solche AGS zu verwenden, die im Verzeichnis geführt sind. Permanente und semipermanente AGS sollten an Betonflächen von Bauwerken und Bauteilen der Bundesverkehrswege gegenüber temporären AGS vorrangig angewendet werden und sind in Kombination mit einer qualitätsgesicherten Ausführung der Bauleistung (Vergabe der Leistungen an Unternehmen die das RAL-Gütezeichen Anti-Graffiti tragen oder gleichwertig) als "Schutzmaßnahme gegen Graffiti" zu empfehlen.
Der vorliegende Forschungsbericht behandelt die Bewertung der Nachhaltigkeit von Erhaltungs- und Ertüchtigungsmaßnahmen an Straßenbrücken. Die Grundlage für die Nachhaltigkeitsbewertung der einzelnen Maßnahmen bildet dabei die in den vorhergehenden Forschungsvorhaben FE 15.0490 "Entwicklung einheitlicher Bewertungskriterien für Infrastrukturprojekte im Hinblick auf die Nachhaltigkeit" (GRAUBNER, 2010) und FE 09.0164 "Einheitliche Bewertungskriterien für Elemente der Straßenverkehrsinfrastruktur im Hinblick auf Nachhaltigkeit - Straße und Tunnel" (FISCHER, 2013) entwickelte Systematik. Ziel des aktuellen Forschungsvorhabens ist es, die vorhandene Systeme zur Nachhaltigkeitsbewertung für die Straßeninfrastrukturelemente Brücke, Tunnel und freie Strecke so zu modifizieren und zu erweitern, dass diese auch für die Beurteilung der Nachhaltigkeit von Erhaltungs- und Ertüchtigungsmaßnahmen an Straßenbrücken einsetzbar sind. Um die relevanten Kriterien für die Bewertung der Nachhaltigkeit zu identifizieren, wurde eine Studie zum prognostizierten Erhaltungsbedarf des Streckenabschnitts Langenbruck-Holledau auf der Bundesautobahn A9 München-Nürnberg herangezogen. Zudem wurden das aktuelle Forschungsvorhabens FE 15.0570 "Verstärkung älterer Beton- und Spannbetonbrücken - Erarbeitung einer Erfahrungssammlung" (SCHNELLENBACH-HELD, 2014) ausgewertet sowie eine weitere Studie zum Einsparpotenzial durch Überprüfung der tatsächlichen Einwirkungen und Widerstände genutzt, um ein möglichst realitätsnahes Bewertungssystem zu erstellen. Die Nachhaltigkeit der einzelnen Erhaltungs- und Ertüchtigungsmaßnahmen soll auf Ebene des übergeordneten Verkehrsnetzes beurteilt werden. Es wurden deshalb verschiedene Betrachtungsebenen zur Beurteilung der Nachhaltigkeit eingeführt mit Hilfe derer die einzelnen Maßnahmen bezüglich ihrer Auswirkungen auf das umgebende Straßennetz überprüft und die Vorteile einer Bündelung bzw. Koordination der einzelnen Maßnahmen aufgezeigt werden können.
Das Forschungsvorhaben verfolgte das Ziel, die Applikation der Oberflächenhydrophobierung bei Betonfahrbahndecken zu optimieren und deren Einfluss auf die schädigende AKR zu bewerten. Die Literaturrecherche zum Stand der Technik ergab, dass bisher primär Silane zur Hydrophobierung von Betonen mit erhöhtem AKR-Schädigungspotenzial im Betonstraßenbau mit unterschiedlichem Erfolg Anwendung fanden. National beschränken sich die Erfahrungen auf den praktischen Einsatz von WA65 auf wenige BAB-Abschnitte (A 9 und A 14). Wissenschaftliche Untersuchungen hierzu fehlen. Vor diesem Hintergrund erfolgten umfangreiche Laboruntersuchungen am Bestands- und Laborbeton zur: - Optimierung der Applikation des Hydrophobierungsmittels, - Bewertung der Dauerhaftigkeit der hydrophobierten Betonrandzone, - Analyse der Auswirkungen der Oberflächenhydrophobierung auf den AKR-Schädigungsprozess. Als Hydrophobierungsmittel kamen die auf dem Wirkstoff Oktyltriethoxysilan basierenden Produkte WA65 und LM7 als Emulsion und GEL30 (Acrylatgel) zum Einsatz. Ihr Verhalten im neu entwickelten Applikationstest war beim Bestandsbeton deutlich schlechter als beim Laborbeton. Hier erwiesen sich WA65 und LM7 als gleichwertig brauchbar, während die geprüfte Modifikation des GEL30 aufgrund seiner geringen Eindringtiefe abzulehnen ist. Bei den aufbauenden Untersuchungen wurden folgende Erkenntnisse gewonnen: - Nachweis der Dauerhaftigkeit der hydrophobierten Betonrandzone im zyklischen Schwingversuch mit aufstehender Prüflösung (exemplarischer Test mit WA65), - Nachweis der Verminderung des AKR-Schädigungsprozesses durch Applikation von WA65 bzw. LM7 auf Bestands- und Laborbeton mittels Klimawechsellagerung (Beaufschlagung mit NaCl-Lösung). Mit einem Langzeitmonitoring des Feuchte- und Salzhaushalts in ausgelagerten Ausbausegmenten mit unterschiedlicher Schadensausprägung im Bereich der Querscheinfuge wird langfristig die dortige Gefahr der Hinterläufigkeit der hydrophobierten Betonrandzone untersucht und bewertet.
Zur Beurteilung der Alkaliempfindlichkeit von Gesteinskörnungen sind im Teil 3 der Alkali-Richtlinie des DAfStb vom Februar 2007 das Schnellprüfverfahren (Referenzprüfverfahren (SPV)) bzw. der Mörtelschnelltest (Alternativverfahren (MST)) und der Betonversuch mit Nebelkammerlagerung (40-°C) (NK) vorgesehen. Bisher war nicht abschließend geklärt, ob die für diese Standardprüfungen festgelegten Beurteilungskriterien auch dann Verwendung finden können, wenn die Gesteinskörnungen in Fahrbahndecken aus Waschbeton (hoher Zementgehalt, besonders gestaltete Oberfläche) angewendet werden sollen. Für die Untersuchungen wurden drei alkaliunempfindliche Splitte (Andesit I Mitteldeutschland (MD), Rhyolith Süddeutschland (SD) und Gabbro), ein alkaliempfindlicher Splitt (Rhyolith MD) und zwei "potenziell" alkaliempfindliche Splitte (Andesit II MD, Granodiorit) verwendet. Die Bewertung der Alkaliempfindlichkeit der sechs groben Gesteinskörnungen auf Basis der Ergebnisse der AKR-Performance-Prüfungen ergab, dass drei von ihnen "geeignet für die Feuchtigkeitklasse WS im Hinblick auf die Vermeidung einer schädigenden Alkali-Kieselsäure-Reaktion (AKR)" sind. Bei ausschließlicher Verwendung der Ergebnisse der Standardprüfverfahren nach Alkali-Richtlinie konnte diese Aussage getroffen werden, wenn eine der folgenden Bedingungen erfüllt war: - Alle Gesteinskörnungsprüfungen nach Teil 3 der Alkali-Richtlinie des DAfStb wurden bestanden. - Der Mörtelschnelltest (Alternativverfahren) nach Teil 3 der Alkali-Richtlinie wurde bestanden. - Der 60-°C-Betonversuch nach Teil 3 der Alkali-Richtlinie wurde bestanden. Die Begünstigung einer schädigenden AKR durch sich von der Oberfläche abhebende Gesteinskörner (Waschbetonoberfläche) konnte bei den untersuchten Betonzusammensetzungen nicht nachgewiesen werden. Im Bereich der Waschbetonoberflächen wurden keine AKR-Reaktionsprodukte gefunden.
Durch vergleichende Untersuchungen an einem RC-Baustoffgemisch, bei dem die Gesteinskörnung aus einem AKR-geschädigten Autobahnabschnitt gewonnen worden ist, und einem Referenzgemisch (ohne AKR-Vorschädigung) sollte die Eignung des AKR-RC-Gemisches als Baustoffgemisch für hydraulisch gebundene Tragschichten untersucht werden. Umfassende Untersuchungen zur Charakterisierung der beiden Ausgangsmaterialien, der Baustoffgemische und an daraus hergestellten HGT-Probekörpern wurden durchgeführt. Im Ergebnis der Untersuchungen kann gezeigt werden, dass das AKR-geschädigte RC-Baustoffgemisch bezüglich seiner körnungsspezifischen Eigenschaften das Potenzial für eine Verwendung als Frostschutzschicht und auch für eine hydraulisch gebundene Tragschicht besitzt. Eine entsprechende Klassierung zum Erreichen bzw. Einstellen der nach Norm geforderten Kennwerte ist ohne weiteres möglich. Auch die erreichbaren Druckfestigkeiten des Baustoffgemisches liegen mit deutlich über 10 N/mm2 (im Mittel 15 N/mm2) in einem Bereich, der das Material für den Anwendungsfall HGT interessant erscheinen lässt. An diesen Festigkeiten ändert sich auch signifikant nichts bei Veränderung der Umgebungsbedingungen (erhöhte Temperaturen bis 40-°C, hohe Luftfeuchten bis 100% und Alkalizufuhr). Deutliche Einschränkungen gelten für das Formänderungsverhalten der mit den AKR-geschädigten RC-Baustoffgemischen hergestellten HGT-Proben, insbesondere dann, wenn diese den reaktionsbeschleunigenden Bedingungen einer AKR-Performance-Prüfung ausgesetzt sind. Die an den Baustoffproben gemessenen Dehnungen sind mit ca. 1 mm/m recht hoch, nicht nur im Vergleich zum aktuell geltenden Grenzwert von 0,5 mm/m (der hier nicht anzusetzen ist), insbesondere im Vergleich zu den Messwerten, die am Referenzmaterial ermittelt werden. Anhand des Kurvenverlaufes ist ersichtlich, dass der Dehnungs-Endwert nach 10 Zyklen noch nicht erreicht ist. Als Ursache für dieses Verhalten muss eine Kombination/Überlagerung aus weiterhin stattfindender schädigender AKR (was durch die Untersuchungen unter dem Mikroskop aber nicht zweifelsfrei bestätigt werden konnte) und einer sekundären Ettringitbildung in Betracht gezogen werden. Aus diesen Ergebnissen sollte eine Verwendung von AKR-geschädigten RC-Baustoffgemischen für HGT für jede Baumaßnahme separat bewertet werden.