A legform impactor with biofidelic characteristics (FlexPLI) which is being developed by the Japanese Automobile Research Institute (JARI) is being considered as a test tool for legislation within a proposed Global Technical Regulation on pedestrian protection (UNECE, 2006) and therefore being evaluated by the Technical Evaluation Group (TEG) of GRSP. In previous built levels it already showed good test results on real cars as well as under idealised test conditions but also revealed further need for improvement. A research study at the Federal Highway Research Institute (BASt) deals with the question on how leg injury risks of modern car fronts can be revealed, reflected and assessed by the FlexPLI and how the impactor can be used and implemented as a legislative instrument for the type approval of cars according to current and future legislations on pedestrian protection. The latest impactor built level (GTα ) is being evaluated by a general review and assessment of the certification procedure, the knee joint biofidelity and the currently proposed injury criteria. Furthermore, the usability, robustness and durability as a test tool for legislation is examined and an assessment of leg injuries is made by a series of tests with the FlexPLI on real cars with modern car front shapes as well as under idealised test conditions. Finally, a comparison is made between the FlexPLI and the current european legislation tool, the legform impactor according to EEVC WG 17.
A flexible pedestrian legform impactor (FlexPLI) has been evaluated by a Technical Evaluation Group (Flex-TEG) of the Working Party on Passive Safety (GRSP) of the United Nations Economic Commission for Europe (UN-ECE). It will be implemented within phase 2 of the global technical regulation (GTR 9) as well as within a new ECE regulation on pedestrian safety as a test tool for the assessment of lower extremity injuries in lateral vehicle-to-pedestrian accidents (UN-ECE 2010-1, 2010-2 and 2010-3). Due to its biofidelic properties in the knee and tibia section, the FlexPLI is found to having an improved knee and tibia injury assessment ability when being compared to the current legislative test tool, the lower legform impactor developed by the Pedestrian Safety Working Group of the European Enhanced Vehicle-safety Committee (EEVC WG 17). However, due to a lack of biofidelity in terms of kinematics and loadings in the femur part of the FlexPLI, an appropriate assessment of femur injuries is still outstanding. The study described in this paper is aimed to close this gap. Impactor tests with the FlexPLI at different impact heights on three vehicle frontends with Sedan, SUV and FFV shape are performed and compared to tests with a modified FlexPLI with upper body mass. Full scale validation tests using a modified crash test dummy with attached FlexPLI that are carried out for the first time prove the more humanlike responses of the femur section with applied upper body mass. Apart from that they also show that the impact conditions described in the current technical provisions for tests with the FlexPLI don"t necessarily compensate the missing torso mass in terms of knee and tibia loadings either. Therefore it can be concluded that an applied upper body mass will contribute to a more biofidelic overall behavior of the legform and subsequently an improved injury assessment ability of all lower extremity injuries addressed by the FlexPLI. Nevertheless, the validity of the original as well as the modified legform for tests against vehicles with extraordinary high bumpers as well as flat front vehicles still needs to be evaluated in detail. A first clue is given by the application of an additional accelerometer to the legform.
The PDB, BASt and Opel conducted two test series to evaluate possible effects on the results obtained using the EEVC WG17 Lower Legform Impactor as a test tool for the assessment of pedestrian safety. The reproducibility and repeatability of the test results were assessed using six legform impactors while keeping the test parameters constant. In the second series one impactor was used and the test parameters were varied to assess the effects on the readings of the legform. The test parameters were velocity, temperature, relative humidity, the point of first contact regarding the deviation in z-direction and the deviations of the pitch, roll and yaw angle. The tests were performed using an inverse setup, i.e. the legform was hit by a guided linear impactor equipped with a honeycomb deformation element. This setup was chosen to be able to vary each single parameter while avoiding variations of the other test parameters at the same time. The test parameters were varied stronger than allowed in regulatory use in order to determine possible dependencies between the parameters and the readings which were acceleration, bending angle and shear displacement.
A flexible pedestrian legform impactor (FlexPLI) with biofidelic characteristics is aimed to be implemented within global legislation on pedestrian protection. Therefore, it is being evaluated by a technical evaluation group (Flex-TEG) of GRSP with respect to its biofidelity, robustness, durability, usability and protection level (Zander, 2008). Previous studies at the Federal Highway Research Institute (BASt) and other laboratories already showed good progress concerning the general development, but also the need for further improvement and further research in various areas. An overview is provided of the different levels of development and all kinds of evaluation activities of the Flex-TEG, starting with the Polar II full scale pedestrian dummy as its origin and ending up with the latest legform impactor built level GTR that is expected to be finalized by the end of the year 2009. Using the latest built levels as a basis, gaps are revealed that should be closed by future developments, like the usage of an upper body mass (UBM), the validation of the femur loads, injury risk functions for the cruciate knee ligaments and an appropriate certification method. A recent study on an additional upper body mass being applied for the first time to the Flex-GT is used as means of validation of recently proposed modified impact conditions. Therefore, two test series on a modern vehicle front using an impactor with and without upper body mass are compared. A test series with the Flex-GTR will be used to study both the comparability of the impact behavior of the GT and GTR built level as well as the consistency of test results. Recommendations for implementation within legislation on pedestrian protection are made.
A series of drop tests and vehicle tests with the adult head impactor according to Regulation (EC) 631/2009 and drop tests with the phantom head impactor according to UN Regulation No. 43 have been carried out by the German Federal Highway Research Institute (BASt) on behalf of the German Federal Ministry of Transport, Building and Urban Development (BMVBS). Aim of the test series was to study the injury risk for vulnerable road users, especially pedestrians, in case of being impacted by a motor vehicle in a way described within the European Regulations (EC) 78/2009 and (EC) 631/2009. Furthermore, the applicability of the phantom head drop test described in UN Regulation No. 43 for plastic glazing should be investigated. In total, 30 drop tests, thereof 18 with the adult head impactor and 12 with the phantom head impactor, and 49 vehicle tests with the adult head impactor were carried out on panes of laminated safety glass (VSG), polycarbonate (PC) and laminated polycarbonate (L-PC). The influence of parameters such as the particular material properties, test point locations, fixations, ambient conditions (temperature and impact angle) was investigated in detail. In general, higher values of the Head Injury Criterion (HIC) were observed in tests on polycarbonate glazing. As the HIC is the current criterion for the assessment of head injury risk, polycarbonate glazing has to be seen as more injurious in terms of vulnerable road user protection. In addition, the significantly higher rebound of the head observed in tests with polycarbonate glazing is suspected to lead to higher neck loads and may also cause higher injury risks in secondary impacts of vulnerable road users. However, as in all tests with PC glazing no damage of the panes was observed, the risk of skin cut injuries may be expected to be reduced significantly. The performed test series give no indication for the test procedure prescribed in UN Regulation No. 43 as a methodology to approve glass windscreen not being feasible for polycarbonate glazing, as all PC panes tested fulfilled the UN R 43 requirements. The performance of the windscreen area will not be relevant for vehicle type approval according to the upcoming UN Regulation for pedestrian protection. However, it is recommended that pedestrian protection being considered for plastic windscreens to ensure at least the same level of protection as glass windscreens.