Sonstige
Fire incidents are among the most relevant for people in a tunnel. Therefore, it is important to be sufficiently prepared for such events. A large scale fire test is to be used to help evaluate the initial burning duration and the time it takes for the fire to spread to other vehicles in the tunnel, and in particular how long it takes for a truck carrying wooden pallets to catch fire, taking into consideration the extremely high temperatures. The goal, therefore, is to determine the time it takes for a fire to spread to other vehicles in the tunnel. In the large scale fire test, an accident in a tunnel with one-way traffic is simulated between a truck loaded with approximately 3.7 t of wooden Europol pallets and a passenger car. Directly behind each of the vehicles involved in the accident there is another car which stops at a distance of 1.0 m. Approximately 300 litres of burning diesel are discharged from the truck's fuel tank, which is simulated by using approximately 400 litres of isopropanol. A 10 m-² burning pool forms underneath the truck. Other objectives of the large scale fire test are the validation of the CFD models and the evaluation of the progression of the thermal release ratios estimated for the simulation. The thermal release ratios generated in the test are determined and evaluated using various models.
Although the bus belongs to the safest traffic means, single accidents can be particularly severe and concern many passengers. Especially in case of fires a high number of injured and killed persons can be the outcome. Fire safety of buses therefore is of high importance. With the increase of plastic materials as a material for the interior equipment of buses and coaches due to their good mechanical properties combined with low weight, the question arises whether the safety level has decreased in case of a fire during the last years " also compared to other means of transport. Because of the combustible plastics and their ability to release a high amount of heat the main fire load in buses is no longer the fuel but the plastic materials which are also often easy to ignite. Besides the flammability of the equipments, also the production of smoke, the smoke development and propagation as well as its toxicity are of interest. That counts for the passengers as well as for the test methods and its limit values. The severe fire in Germany near Hanover in 2008 with 20 fatalities showed how disastrous such fires can be. For those reasons several research projects were initiated on behalf of the German Federal Highway Research Institute. At the one hand the fire behaviour of coach interiors was examined in general focusing on fire propagation as well as fire detection and signalling. As result, recommendations with regard to early fire detection systems for the engine compartments and onboard extinguishing equipment were elaborated. On the other hand research was carried out to examine heat release, smoke, smoke propagation and its toxicity due to burning bus interior materials. In this project small and real scale experiments on material specimens, interior parts and vehicles were performed. Trains and buses often have very similar operation conditions. Consequently, bus interior material was tested according to the regulations for rail vehicles, i.e. DIN EN 45545 as well as DIN 5510. None of the tested bus interior materials would have been allowed to use in a train. The fire safety regulations for bus materials are on a low level compared to other transport sectors, i.e. railway, ship and aircraft. Also numerical investigations with the Fire Dynamics Simulator (FDS) were performed. The very rapid fire development during the severe bus fire from 2008 could be predicted with the numerical model. The model was then used to investigate the influence of different materials, ventilation conditions and ignition sources. The bus materials contribute significantly to a very rapid fire development in bus fires. Especially, the flammable ceiling and the passenger seats were identified to be key issues of the fire propagation in a bus and can be explained by the rapid fire spread along the ceiling and the high fire load of passenger seats. As conclusion of the project effective and economically reasonable fire safety requirements for interiors of buses are recommended which would improve the current situation. Proposals for amendments of current requirements are recommended including the specification of appropriate limit values. In particular, it is taken into consideration which reasonable fire safety standards from other transport sectors, especially the rail sector, should be transferred to buses
Immediate user self-evacuation is crucial in case of fire in road tunnels. This study investigated the effects of information with or without additional virtual reality (VR) behavioural training on self-evacuation during a simulated emergency situation in a road tunnel. Forty-three participants were randomly assigned to three groups with accumulating preventive training: The control group only filled in questionnaires, the informed group additionally read an information brochure on tunnel safety, and the VR training group received an additional behavioural training in a VR tunnel scenario. One week later, during the test session, all participants conducted a drive through a real road tunnel in which they were confronted with a collision of two vehicles and intense smoke. The informed and the behaviourally trained participants evacuated themselves more reliably from the tunnel than participants of the control group. Trained participants showed better and faster behavioural responses than informed only participants. Interestingly, the few participants in the control group who reacted adequately to the scenario were all female. A 1 year follow-up online questionnaire showed a decrease of safety knowledge, but still the trained group had somewhat more safety relevant knowledge than the two other groups. Information and especially VR behavioural training both seem promising to foster adequate self-evacuation during crisis situations in tunnels, although long term beneficial behavioural effects have to be demonstrated. Measures aiming to improve users/ behaviour should take individual difference such as gender into account.
An analysis of NASS and FARS was conducted to determine crash conditions that involved injuries that are not currently being directly addressed by vehicle safety standards or by consumer information test protocols. Analysis of both field data and US NCAP tests were conducted to determine the relative safety provided by seating position and by vehicle model year. Opportunities for improvements were determined by crash categories with large populations of injuries that were not addressed by safety tests or smaller numbers that were increasing in frequency. Areas of opportunities include improved occupant restrain in rollovers, improved frontal protection for rear seat occupants and improved fire prevention in frontal and rollover crashes.