31 Bituminöse Baustoffe
The performance of asphalt by low temperatures is largely determined by the viscosity of the binder respectively the mortar of the asphalt. The traditional test methods for binder (e.g. ball-draw viscosimeter) are limited to temperatures above the service range of temperature for an asphalt construction. The Dynamic Shear Rheometer (DSR) is limited to temperatures above 30-°C whereas the Bending Beam Rheometer (BBR) is limited to temperatures below -10-°C and not applicable to mortar. Especially the gap in the temperature of these test methods is very important to characterize the viscosity behavior of binder and mortar over the whole range of the service temperatures, which represent the typical environmental conditions of over the seasons, for an asphalt construction. Tension retardation experiments seem to be very useful to bridge the gap. They address the low temperature behavior of binder and mortar. With this test method the flow characteristics of binder (pen grade and any modification) and any kind of mortar in the service temperature range, in particular at low temperatures of -25-°C can be determined with a high precision, and assessed, via the physically interpretable material characteristics quantity of tension viscosity. Furthermore the present findings indicate the potential of extrapolation the results of the Tension retardation for a prediction of the rutting resistance of asphalt mixtures. As part of several research Projects, BASt (Federal Highway Research Institute) investigated the effects of different modifications of the binder to low temperature behavior of the binder by the tension retardation test. This paper is intended to provide a more detailed description of the test method Tension Retardation, selected results and related findings.
Die Verformungseigenschaften von Asphaltschichten, ausgedrückt durch den Asphalt-E-Modul, werden wesentlich von deren Temperatur bestimmt. Bei der Beantwortung verschiedenster Fragestellungen aus dem Bereich des Neubaus und der Erhaltung von Asphaltstraßen muss diese Temperaturabhängigkeit des Asphaltes berücksichtigt werden. In Deutschland existiert bislang keine breite empirisch ermittelte Datenbasis, welche Asphaltkörpertemperaturen in verschiedenen Tiefen und zu verschiedenen Tages- und Jahreszeiten beschreibt. Im Rahmen eines Forschungsvorhabens, gefördert durch die Deutsche Forschungsgemeinschaft (DFG), wurden durch das Institut für Straßenbau und Verkehrswesen der Universität Duisburg-Essen im Jahr 2007 an zwei bestehenden Straßen Temperatursensoren dauerhaft verbaut, welche die Asphaltkörpertemperatur in verschiedenen Tiefen kontinuierlich aufzeichnen.