A flexible pedestrian legform impactor (FlexPLI) has been evaluated by a Technical Evaluation Group (Flex-TEG) of the Working Party on Passive Safety (GRSP) of the United Nations Economic Commission for Europe (UN-ECE). It will be implemented within phase 2 of the global technical regulation (GTR 9) as well as within a new ECE regulation on pedestrian safety as a test tool for the assessment of lower extremity injuries in lateral vehicle-to-pedestrian accidents (UN-ECE 2010-1, 2010-2 and 2010-3). Due to its biofidelic properties in the knee and tibia section, the FlexPLI is found to having an improved knee and tibia injury assessment ability when being compared to the current legislative test tool, the lower legform impactor developed by the Pedestrian Safety Working Group of the European Enhanced Vehicle-safety Committee (EEVC WG 17). However, due to a lack of biofidelity in terms of kinematics and loadings in the femur part of the FlexPLI, an appropriate assessment of femur injuries is still outstanding. The study described in this paper is aimed to close this gap. Impactor tests with the FlexPLI at different impact heights on three vehicle frontends with Sedan, SUV and FFV shape are performed and compared to tests with a modified FlexPLI with upper body mass. Full scale validation tests using a modified crash test dummy with attached FlexPLI that are carried out for the first time prove the more humanlike responses of the femur section with applied upper body mass. Apart from that they also show that the impact conditions described in the current technical provisions for tests with the FlexPLI don"t necessarily compensate the missing torso mass in terms of knee and tibia loadings either. Therefore it can be concluded that an applied upper body mass will contribute to a more biofidelic overall behavior of the legform and subsequently an improved injury assessment ability of all lower extremity injuries addressed by the FlexPLI. Nevertheless, the validity of the original as well as the modified legform for tests against vehicles with extraordinary high bumpers as well as flat front vehicles still needs to be evaluated in detail. A first clue is given by the application of an additional accelerometer to the legform.
A biofidelic flexible pedestrian legform impactor (FlexPLI) has been developed from the year 2000 onwards and evaluated by a technical evaluation group (Flex-TEG) of UN-ECE GRSP. A recently established UN-ECE GRSP Informal Group on GTR9 Phase 2 is aiming at introducing the FlexPLI within world-wide regulations on pedestrian safety (Phase 2 of GTR No. 9 as well as the new UN regulation 127 on pedestrian safety) as a test tool for the assessment of lower extremity injuries in lateral vehicle-to-pedestrian accidents. Besides, the FlexPLI has already been introduced within JNCAP and is on the Euro NCAP roadmap for 2014. Despite of the biofidelic properties in the knee and tibia sections, several open issues related to the FlexPLI, like the estimation of the cost benefit, the feasibility of vehicle compliance with the threshold values, the robustness of the impactor and of the test results, the comparability between prototype and production level and the finalization of certification corridors still needed to be solved. Furthermore, discussions with stakeholders about a harmonized lower legform to bumper test area are still going on. This paper describes several studies carried out by the Federal Highway Research Institute (BASt) regarding the benefit due to the introduction of the FlexPLI within legislation for type approval, the robustness of test results, the establishment of new assembly certification corridors and a proposal for a harmonized legform to bumper test area. Furthermore, a report on vehicle tests that previously had been carried out with three prototype legforms and were now being repeated using legforms with serial production status, is given. Finally, the paper gives a status report on the ongoing simulation and testing activities with respect to the development and evaluation of an improved test procedure with upper body mass for assessing pedestrian femur injuries.
A flexible pedestrian legform impactor (FlexPLI) with biofidelic characteristics is aimed to be implemented within global legislation on pedestrian protection. Therefore, it is being evaluated by a technical evaluation group (Flex-TEG) of GRSP with respect to its biofidelity, robustness, durability, usability and protection level (Zander, 2008). Previous studies at the Federal Highway Research Institute (BASt) and other laboratories already showed good progress concerning the general development, but also the need for further improvement and further research in various areas. An overview is provided of the different levels of development and all kinds of evaluation activities of the Flex-TEG, starting with the Polar II full scale pedestrian dummy as its origin and ending up with the latest legform impactor built level GTR that is expected to be finalized by the end of the year 2009. Using the latest built levels as a basis, gaps are revealed that should be closed by future developments, like the usage of an upper body mass (UBM), the validation of the femur loads, injury risk functions for the cruciate knee ligaments and an appropriate certification method. A recent study on an additional upper body mass being applied for the first time to the Flex-GT is used as means of validation of recently proposed modified impact conditions. Therefore, two test series on a modern vehicle front using an impactor with and without upper body mass are compared. A test series with the Flex-GTR will be used to study both the comparability of the impact behavior of the GT and GTR built level as well as the consistency of test results. Recommendations for implementation within legislation on pedestrian protection are made.
A legform impactor with biofidelic characteristics (FlexPLI) which is being developed by the Japanese Automobile Research Institute (JARI) is being considered as a test tool for legislation within a proposed Global Technical Regulation on pedestrian protection (UNECE, 2006) and therefore being evaluated by the Technical Evaluation Group (TEG) of GRSP. In previous built levels it already showed good test results on real cars as well as under idealised test conditions but also revealed further need for improvement. A research study at the Federal Highway Research Institute (BASt) deals with the question on how leg injury risks of modern car fronts can be revealed, reflected and assessed by the FlexPLI and how the impactor can be used and implemented as a legislative instrument for the type approval of cars according to current and future legislations on pedestrian protection. The latest impactor built level (GTα ) is being evaluated by a general review and assessment of the certification procedure, the knee joint biofidelity and the currently proposed injury criteria. Furthermore, the usability, robustness and durability as a test tool for legislation is examined and an assessment of leg injuries is made by a series of tests with the FlexPLI on real cars with modern car front shapes as well as under idealised test conditions. Finally, a comparison is made between the FlexPLI and the current european legislation tool, the legform impactor according to EEVC WG 17.
Recent accident statistics from the German national database state bicyclists being the second endangered group of vulnerable road users besides pedestrians. With 399 fatalities, more than 14.000 seriously injured and more than 61.000 slightly injured persons on german roads in the year 2011, the group of bicyclists is ranked second of all road user groups (Statistisches Bundesamt, 2012). While the overall bicycle helmet usage frequency in Germany is very low, evidence is given that its usage leads to a significant reduction of severe head injuries. After an estimation of the benefit of bicycle helmet usage as well as an appropriate test procedure for bicyclists, this paper describes two different approaches for the improvement of bicyclist safety. While the first one is focusing on the assessment of the vehicle based protection potential for bicyclists, the second one is concentrating on the safety assessment of bicycle helmets. Within the first part of the study the possible revision of the existing pedestrian testing protocols is being examined, using in depth accident data, full scale simulation and hardware testing. Within the second part of the study, the results of tests according to supplemental test procedures for the safety assessment of bicycle helmets developed by the German Federal Highway Research Institute (BASt) are presented. An additional full scale test performed at reduced impact speed proves that measures of active vehicle safety as e.g. braking before the collision event do not necessarily always lead to a reduction of injury severity.
The PDB, BASt and Opel conducted two test series to evaluate possible effects on the results obtained using the EEVC WG17 Lower Legform Impactor as a test tool for the assessment of pedestrian safety. The reproducibility and repeatability of the test results were assessed using six legform impactors while keeping the test parameters constant. In the second series one impactor was used and the test parameters were varied to assess the effects on the readings of the legform. The test parameters were velocity, temperature, relative humidity, the point of first contact regarding the deviation in z-direction and the deviations of the pitch, roll and yaw angle. The tests were performed using an inverse setup, i.e. the legform was hit by a guided linear impactor equipped with a honeycomb deformation element. This setup was chosen to be able to vary each single parameter while avoiding variations of the other test parameters at the same time. The test parameters were varied stronger than allowed in regulatory use in order to determine possible dependencies between the parameters and the readings which were acceleration, bending angle and shear displacement.