Immediate user self-evacuation is crucial in case of fire in road tunnels. This study investigated the effects of information with or without additional virtual reality (VR) behavioural training on self-evacuation during a simulated emergency situation in a road tunnel. Forty-three participants were randomly assigned to three groups with accumulating preventive training: The control group only filled in questionnaires, the informed group additionally read an information brochure on tunnel safety, and the VR training group received an additional behavioural training in a VR tunnel scenario. One week later, during the test session, all participants conducted a drive through a real road tunnel in which they were confronted with a collision of two vehicles and intense smoke. The informed and the behaviourally trained participants evacuated themselves more reliably from the tunnel than participants of the control group. Trained participants showed better and faster behavioural responses than informed only participants. Interestingly, the few participants in the control group who reacted adequately to the scenario were all female. A 1 year follow-up online questionnaire showed a decrease of safety knowledge, but still the trained group had somewhat more safety relevant knowledge than the two other groups. Information and especially VR behavioural training both seem promising to foster adequate self-evacuation during crisis situations in tunnels, although long term beneficial behavioural effects have to be demonstrated. Measures aiming to improve users/ behaviour should take individual difference such as gender into account.
This paper deals with possibilities to update existing road tunnels in order to fulfill up to date requirements regarding structural fire protection. Besides the upgrading of tunnels with structural fire protection systems (like e.g. fire protection sheets) there is also the possibility of numerical investigations. In research projects carried out on behalf of the Federal Highway Research Institute (BASt) numerical investigations for the proof of sufficient structural fire protection have been done for common road tunnel types. Additionally the influence of different fire loads and fire durations on the bearing capacity of the structures have been investigate existing tunnels regarding structural fire protection. The research results have also been the basis for a current update of national standards for tunnel construction.
Although the bus belongs to the safest traffic means, single accidents can be particularly severe and concern many passengers. Especially in case of fires a high number of injured and killed persons can be the outcome. Fire safety of buses therefore is of high importance. With the increase of synthetic and plastic materials as a material for the interior equipment of buses and coaches because of their ood mechanical properties combined with low weight, the question arises whether the safety level has decreased in case of a fire during the last years - also compared to other means of transport. Because of the combustible plastics and their ability to release a high amount of heat the main fire load in buses is no longer the fuel but the plastic materials which are also often easy to ignite. Besides the flammability of the equipments, the production of smoke, the smoke development and propagation and its toxicity for the people as well as the testing methods and limit values are of interest. For those reasons research projects were initiated on behalf of the German Federal Highway Research Institute. At the one hand the fire behavior of coach interiors was examined in general focusing on fire propagation as well as fire detection and signalling. As result, recommendations with regard to early fire detection systems for the engine compartments and on-board extinguishing equipment were elaborated. At the other hand research is carried out to examine heat release, smoke, smoke propagation and its toxicity due to burning bus interior materials. The paper describes which effective and economically reasonable fire safety requirements for interiors of buses would improve the current situation. Proposals for amendments of current requirements are recommended including the specification of appropriate limit values. In particular, it is taken into consideration which reasonable fire safety standards from other transport sectors, especially the rail sector, should be transferred to buses.
An analysis of NASS and FARS was conducted to determine crash conditions that involved injuries that are not currently being directly addressed by vehicle safety standards or by consumer information test protocols. Analysis of both field data and US NCAP tests were conducted to determine the relative safety provided by seating position and by vehicle model year. Opportunities for improvements were determined by crash categories with large populations of injuries that were not addressed by safety tests or smaller numbers that were increasing in frequency. Areas of opportunities include improved occupant restrain in rollovers, improved frontal protection for rear seat occupants and improved fire prevention in frontal and rollover crashes.