Filtern
Dokumenttyp
Sprache
- Englisch (2) (entfernen)
Schlagworte
- Verteilung (mater) (2) (entfernen)
Institut
This article reports on a two-year study (2006 to 2008) of the distribution of de-icing salts (NaCl) applied to the road and the influence of traffic on the effective times of the de-icing salts. The research was focused on the needed resting periods of de-icing salts on road surfaces. The study used sensors installed in two lanes of the Motorway A4 in the area of the Dresden-Hellerau Highway Surveillance Center (Germany), to measure air and ground temperatures, wind speed and direction, liquid film thicknesses and residual quantities of salt on the road surface during ongoing traffic at 5-minute intervals. The authors conclude with four observations that can be useful for applying de-icing salts more judiciously: preventive spreading is only sensible if applied timely, i.e. immediately prior to icing events to be expected; the time-frame for preventive spreading on the dry road surface is maximum 60 minutes and on the moist road surface maximum 120 minutes; by increasing spreading densities in preventive spreading, this timeframe cannot be extended; it is completely sufficient if the spreading width is adjusted in such a way that the outer wheel tracks are also covered by the spreading. Distribution across the entire width of the lane will be caused by the rolling traffic within a few minutes.
Although the bus belongs to the safest traffic means, single accidents can be particularly severe and concern many passengers. Especially in case of fires a high number of injured and killed persons can be the outcome. Fire safety of buses therefore is of high importance. With the increase of plastic materials as a material for the interior equipment of buses and coaches due to their good mechanical properties combined with low weight, the question arises whether the safety level has decreased in case of a fire during the last years " also compared to other means of transport. Because of the combustible plastics and their ability to release a high amount of heat the main fire load in buses is no longer the fuel but the plastic materials which are also often easy to ignite. Besides the flammability of the equipments, also the production of smoke, the smoke development and propagation as well as its toxicity are of interest. That counts for the passengers as well as for the test methods and its limit values. The severe fire in Germany near Hanover in 2008 with 20 fatalities showed how disastrous such fires can be. For those reasons several research projects were initiated on behalf of the German Federal Highway Research Institute. At the one hand the fire behaviour of coach interiors was examined in general focusing on fire propagation as well as fire detection and signalling. As result, recommendations with regard to early fire detection systems for the engine compartments and onboard extinguishing equipment were elaborated. On the other hand research was carried out to examine heat release, smoke, smoke propagation and its toxicity due to burning bus interior materials. In this project small and real scale experiments on material specimens, interior parts and vehicles were performed. Trains and buses often have very similar operation conditions. Consequently, bus interior material was tested according to the regulations for rail vehicles, i.e. DIN EN 45545 as well as DIN 5510. None of the tested bus interior materials would have been allowed to use in a train. The fire safety regulations for bus materials are on a low level compared to other transport sectors, i.e. railway, ship and aircraft. Also numerical investigations with the Fire Dynamics Simulator (FDS) were performed. The very rapid fire development during the severe bus fire from 2008 could be predicted with the numerical model. The model was then used to investigate the influence of different materials, ventilation conditions and ignition sources. The bus materials contribute significantly to a very rapid fire development in bus fires. Especially, the flammable ceiling and the passenger seats were identified to be key issues of the fire propagation in a bus and can be explained by the rapid fire spread along the ceiling and the high fire load of passenger seats. As conclusion of the project effective and economically reasonable fire safety requirements for interiors of buses are recommended which would improve the current situation. Proposals for amendments of current requirements are recommended including the specification of appropriate limit values. In particular, it is taken into consideration which reasonable fire safety standards from other transport sectors, especially the rail sector, should be transferred to buses